TT3756.History output of specified time.pdf - 第3页
SMT Software Engineeri ng Group IMOperationsYAMAHAMOTORCO. ,LTD. MD OC-SOFT50042 3/6 3. Settin gs 3.1. Se ttings of the “histo ry output of specified time” function Please o pen [Software Sett in…

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50042
2/6
1. Introduction
The target model and the target version of this specification are as follows.
Table 1.1 Target model and object version of this function
Item name Object Remarks
Target model YS Series Mounter, YG12 Series Mounter, YG300
Object version V3.10STD R1.000 or later
2. Summary
This function is to set the file outputting time of history file [MIS] and [Unit log] freely. (Until now,
these files were outputted by fixed 0:00 o'clock)
In addition to that, a resetting operation (history deletion) can be used when [Unit Log] file is
outputted.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50042
3/6
3. Settings
3.1. Settings of the “history output of specified time” function
Please open [Software Setting] - [History] - [Detail History Setting].
• [The history is output at specified time] Check Box
Check the “checked state” when you specify output time of the history file.
The default setting is “unchecked state”, in this case, the history file is outputted at 0:00.
When the check box is “checked state”, the previous version setting which is outputted at 0:00
o'clock is not executed.
• [Specified time] Text Box
Set the output time (from 0:00 to 23:59) of the history file.
• [After the history output, the unit logs are reset] Check Box
It is the same operation as the tapping [Unit Log] – [(each history)] – [Operator] - [Reset] button
after the history file is outputted.
4. Details
4.1. Output target of the history file
The output target of the history files are as follows.
・MIS-----Error log, Board log, Program log, Setup log
・Unit Log----- Head, Nozzle, Feeder, Conveyor, Parts, Feeder ID
(The [MIS by Board] history is not included in this function.)

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50042
4/6
4.2. Reset operation
[Unit Log] is reset after the history is saved.
It is the same operation as the tapping [reset] button under the history screen.
After the operation is completed, [Ea12779: The auto reset of History data was executed.] is
recorded in [MIS] - [Log].
4.2.1. Reset target of the History
The following screens of [Unit Log] are reset.
・"Operator" information on Head, Nozzle, Feeder, Conveyor and Feeder ID
・"Current data" information on parts history
4.2.2. Notice of reset operation
When the machine is turned off in the specified time, the reset process is done at the next
machine started.
(The data until the day before is saved at the machine turn-off.)
4.3. Saving history to the server folder
When the server folder is specified on [Software Setting] - [History] - [MIS setting] or [Unit log
setting], the history file is saved in the each day file.
4.3.1. Common items of the each history
The history file is saved as the date character is added to the each history item name.
This rule is applied to saving the history in arbitrary timing.
item name + date . csv
Fixed character
It is decided according to the judgment standard of
the each history. (Refer to 4.3.2 decision items of
the each history)
It is decided according to the kinds of the history.