JX-300LED_QA表.pdf - 第6页

QA表 NO. 1 (1/2) NO. 1 (2/2) 机种 确认方法 杆张力压吸嘴中心,测定吸嘴被压进时的力量。 LNC,IC 贴装头(通用) 组装后吸嘴开放应在 15.68N (1.6kgf) 以下的力量下顺利移动。 Z滑动轴 吸嘴套 杆张力 故障原因 1.吸嘴套轴、吸嘴套轴IC、吸嘴套、吸嘴套SP元件不良 吸嘴套 2.润滑脂涂抹量过少。 A部 Z马达转矩,影响吸嘴更换。 调整方法 1.更换零件。 2.向吸嘴套的A部涂硅胶润滑脂 (…

100%1 / 92
Rev 1.0
QA
基板夹紧动作的稳定(夹紧杆的升降) ··································································································8-13
基板夹紧的 ON/OFF 检出(夹紧传感器)·····························································································8-14
9ATC···················································································· 9-1
ATC 传感器配件调整··········································································································································· 9-1
速度控制器调整····················································································································································· 9-2
ATC 底板上面明面度··········································································································································· 9-3
ATC、校准板的位置调整·································································································································· 9-4
10】空气关系 ···········································································10-1
压力检测传感器···················································································································································10-1
压力调整··································································································································································10-2
VAC-CAL(真空发生器) ······························································································································10-3
VAC-CAL(真空泵)········································································································································10-4
11】电气 ·················································································11-1
XY 轴伺服放大器的轴设置 ·····························································································································11-1
Z/θ 轴伺服放大器的轴设置 ···························································································································11-2
DC 电源输出电压 ················································································································································11-3
传送步进马达驱动电流 ····································································································································11-4
自动宽度调整用步进马达驱动电流············································································································11-5
基板检测传感器灵敏度(IN/OUT/STOP/C.OUT/STOP (1200)/STOP (1500)··················11-6
基板检测传感器灵敏度(BU.PIN ············································································································11-7
BASE-FEEDER 基板的 A/D 变换调整 ·······································································································11-8
贴装头真空电平···················································································································································11-9
HMS 回路的调整··············································································································································· 11-10
LIGHT CTRL PCB ASM 基准电压············································································································ 11-11
数字压力开关的设定(ISE30A·············································································································· 11-12
基板检测传感器灵敏度 (WAIT) HPX-EG00-1S ················································································· 11-13
QA表 NO. 1 (1/2) NO. 1 (2/2)
机种
确认方法
杆张力压吸嘴中心,测定吸嘴被压进时的力量。
LNC,IC贴装头(通用)
组装后吸嘴开放应在15.68N (1.6kgf) 以下的力量下顺利移动。
Z滑动轴 吸嘴套 杆张力
故障原因
1.吸嘴套轴、吸嘴套轴IC、吸嘴套、吸嘴套SP元件不良 吸嘴套
2.润滑脂涂抹量过少。
A部
Z马达转矩,影响吸嘴更换。 调整方法
1.更换零件。
2.向吸嘴套的A部涂硅胶润滑脂(G-40M)。
发生Z马达超符合异常。
吸嘴更换异常
NO
NO. 担当人
【1】-1
L151E821000 吸嘴套SP
40046632
IC Z滑动轴40078035
装置名称 贴装头(LNC,IC贴装头)
40044586 Z滑动轴 LNC,IC贴装头 (KE2080)
吸嘴套
功能作用(规格调整值的意义)
变更履历
IC贴装头 (KE2080R)
日期
预想故障(应规格调整值不良而发生的故障)
对象元件
品名 有关质量特性货号
内容
确认方法及调整方法(故障处理方法)
功能名称 吸嘴套动作 编制日期
JX-300LED
质量保证类别  功能安全性 / 可靠性 / 安全性 / 商品特点
质量特性(规格调整值)
QA表 NO. 2 (1/2) NO. 2 (2/2)
机种
确认方法
使用转矩测定装置,测定吸嘴开始旋转时的转矩。
LNC,IC贴装头(通用)
吸嘴(检查合格品)在0.020Nm (0.20kgfcm) 以下转矩时不能旋转。
Z滑动轴 吸嘴套 吸嘴
故障原因
1.吸最套轴、吸嘴套轴IC、吸嘴套、吸嘴套SP零件不良。
吸嘴在θ轴旋转动作时防止吸嘴套轴偏斜。 调整方法
1.更换零件。
贴装精度不良
吸嘴更换异常
吸嘴损坏
NO
NO. 担当人
【1】-2
变更履历
内容
质量保证类别  功能安全性 / 可靠性 / 安全性 / 商品特点
编制日期功能名称 吸嘴夹持力
功能作用(规格调整值的意义)
预想故障(应规格调整值不良而发生的故障)
对象元件
质量特性(规格调整值)
货号 品名 有关质量特性
装置名称JX-300LED
40044586 Z滑动轴 LNC,IC贴装头 (KE2080)
40078035 IC Z滑动轴 IC贴装头 (KE2080R)
贴装头(LNC,IC贴装头) 确认方法及调整方法(故障处理方法)
日期
40046632 吸嘴套
L151E821000 吸嘴套SP