00198442-04_UM_TX-V2_EN.pdf - 第118页

3 Technical data and assemblie s Instruction manual SIPLACE TX 3.5 Placement head From software version 714.0 12/2020 118 3.5.1.1 Overview 3 3 Fig. 3.5 - 1 SIPLACE SpeedSt ar - overview (1) Connection for the holding cir…

100%1 / 330
Instruction manual SIPLACE TX 3 Technical data and assemblies
From software version 714.0 12/2020 3.5 Placement head
117
3.5 Placement head
3.5.1 SIPLACE SpeedStar C&P20 P2 on the SIPLACE TX
The SIPLACE TX uses the SIPLACE SpeedStar C&P20 P2 for top placement performance.
3
CAUTION
Always take hold of the handle to push the placement head
The placement head may only be moved by pushing manually against the handle provid-
ed.
3 Technical data and assemblies Instruction manual SIPLACE TX
3.5 Placement head From software version 714.0 12/2020
118
3.5.1.1 Overview
3
3
Fig. 3.5 - 1 SIPLACE SpeedStar - overview
(1) Connection for the holding circuit of the vacuum pump
(2) "Intermediate distributor" board (under the cover)
(3) Handle
(4) Star motor
(5) DP drive
(6) Nozzle
(7) Pressure control valve
(8) Z motor (linear motor)
(9) Return cylinder
(5)
(1)
(7)
(2)
(3)
(4)
(6)
(8)
(9)
Instruction manual SIPLACE TX 3 Technical data and assemblies
From software version 714.0 12/2020 3.5 Placement head
119
3.5.1.2 Technical data for SIPLACE SpeedStar (C&P20 P2)
3
SIPLACE SpeedStar(C&P20 P2)
With component camera type 48
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-
specific standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD,
Bare-Die, Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
2 mm
*b
/ 4 mm
70 µm
30 µm
100 µm
50 µm
0.12 mm x 0.12 mm
8.2 mm x 8.2 mm
1 g
*)b Only 2 mm possible for SIPLACE TX2i.
Set-down force 1.3 N ± 0.5N (default value)
0.5 N - 4.5 N
Touchless Placement
Nozzle types 40xx/60xx
X/Y accuracy
*c
Standard
*)c The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
± 25 µm/3σ
Angular accuracy ± 0.5° / 3σ
Illumination level 5