00194422-09_MM_X-Series_en.pdf - 第36页
Major Maintenance Maintenance Tasks for Base Machine 5.2.3 Performing Maintenance Tasks 36 Maintenance Manual SIPLACE X Series 5.2.3.2 5 . 2 . 3 . 2 C le a n in g t h e G a s P r e s s u r e S h o c k A b s o r b e r s o…

Major Maintenance
5.2.3 Performing Maintenance Tasks Maintenance Tasks for Base Machine
Maintenance Manual SIPLACE X Series 35
Monitoring the Reject Bin
Conveyor - Monitoring the Nozzle Magazines
Monitoring the Nozzle Magazines
► Remove the nozzle reject bin (1). A message should
immediately appear on the control panel.
NOTICE!
If no message appears, have the safety circuit checked
and any damaged components replaced by authorized
personnel or the SIPLACE Service team.
► Reinsert the nozzle reject bin.
► Remove the component reject bin (2). A message
should immediately appear on the control panel.
NOTICE!
Monitoring the component reject bin is optional.
If no message appears, check whether this option is in
-
stalled on your system.
If the option is installed and no message appears, have
the safety circuit checked and, if required, any damaged
components replaced by authorized personnel or the
SIPLACE Service team.
► Reinsert the component reject bin.
► Repeat the procedure for all reject bins.
NOTICE!
Twin magazines are permanently fixed and cannot be re
-
moved. For this reason, this check is not applicable for
Twin magazines.
► Remove the nozzle magazines.
► Close the covers and press the Start button.
⇨ Depending on the station software, the station must
display all removed nozzle magazines.

Major Maintenance
Maintenance Tasks for Base Machine 5.2.3 Performing Maintenance Tasks
36 Maintenance Manual SIPLACE X Series
5.2.3.2
5.2.3.2 Cleaning the Gas Pressure Shock Absorbers on the Protective Covers
Cleaning the Gas Pressure Shock Absorbers on the Protective Covers
5.2.3.3
5.2.3.3 Check/replace the gas pressure shock absorbers on the protective covers
Check/replace the gas pressure shock absorbers on the protective covers
► Open the protective covers.
► Wipe the sliding surfaces of the gas pressure shock
absorbers (1) clean with a lint-free cloth.
► There should be no oil visible on the pistons: other
-
wise replace the gas pressure shock absorbers.
For removal and installation details, read the service
manual for your machine.
► Close the machine safety covers.
► Open the protective cover (1).
► Pull the protective cover approx. 30 cm downwards
and then release it again.
If the cover does not open completely again and if
there is play in the uppermost position (approx. 20
mm), replace the gas pressure shock absorbers.
For removal and installation details, refer to the Ser
-
vice manual for your machine.
► Pull the protective cover vertically to a position be
-
tween the top and bottom positions and then release
it again.
The cover must stay in position without help. If it clos
-
es on its own, replace the gas pressure shock ab
-
sorbers.
For removal and installation details, read the service
manual for your machine.
► Close the protective cover.
► Repeat these steps for all protective covers.

Major Maintenance
5.2.3 Performing Maintenance Tasks Maintenance Tasks for Base Machine
Maintenance Manual SIPLACE X Series 37
5.2.3.4
5.2.3.4 Checking and Cleaning/Replacing the Compressed Air Filter (if required)
Checking and Cleaning/Replacing the Compressed Air Filter (if required)
CAUTION!
Before checking or replacing the compressed air filters,
you need to shut off the supply of air!
► Use the machine key to open the door to the com
-
pressed air supply, detach the cable and remove the
door.
► Turn the main compressed air valve (1) clockwise. All
manometers must be set to zero.
► Loosen the screw (2) , and pull out the compressed
air supply.
► Place the collecting vessel under the compressed air
supply.
► Open the screw (1) beneath the cover cap (2) to re
-
lease the pressure.
► Pull the locking lever (1) on the cover downwards.
Press the cover (2) upwards and unscrew by turning
to the left (3).
► Unscrew the compressed air filter (4) and check for
dirt.
► Replace the filter if it is dirty.
⇨ Filter element 5 μm [03050213-xx]
HSxx / D1 / D2 / D4 / SX series / X series from
March 2008 pneumatic valve [03062274-xx]
(for [03060279-xx] pneumatic unit)
⇨ Replacement filter for 5 μm compressed air filter
for pneumatic valve [03038979-xx]
X series up to SN B089 [03004680-xx]
(for [03004151-xx] pneumatic unit)
⇨ Filter element for 5 μm filter (new) for pneumatic
valve [03039182-xx]
X series from SN B090 [03038691-xx]
(for [03038058-xx] pneumatic unit)