Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLAC E S-25 HM / S-27 HM / HS-50 / HS-60 / HF -series / X-series 11/2006 Edition 52 : Remove the cover plate for the ODU co nnector by loosening the two screws. The co…

100%1 / 60
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
51
2.10 Retrofit the SIPLACE HF-series / X-series
2.10.1 Work at the location
: Dock the component trolley out of the placement machine.
: Shut down the placement system and switch it off.
2
: Remove the nozzle reject bin and component reject bin.
: Remove all nozzle changers fitted at this location.
2
If the reject bin sensor option is installed, it must be removed and refitted later. 2
2
: Close the air connections.
: Stow the unused cables in the cable duct.
2
Reject bin sensor
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
52
: Remove the cover plate for the ODU connector by loosening the two screws. The cover plate
can be removed with a light rotary movement forward.
2
: Remove the tape guide channel by loosening these two screws.
2
Inside the machine, the cover plate must be pulled inwards slightly so that the tape guide channel
can be removed. 2
2
Screws
Screws
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
53
: Fit the new tape guide channel together with the cover plate (left screw).
Tighten it with both screws left and right.
If necessary, tighten the cover plate on the right side with M5x8 screw.
2
2
2
2
2
2
2
2
2
2
2
2
2
Screws
Cover plate
M5x8 screw