56
: Refit the reject bin sensor option, if present.
: Dock the component trolley on the machine and screw the safety bars with M6x30 screws
--> Risk of head crash
2
2
2
2
2
Safety bar
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
57
2
2
As you dock the component trolley, make sure that it does not collide with the fitted tape guide
channel. 2
2
2.10.2 Working on the component trolley
: Remove the feeder fixing on the component trolley if present.
2.10.3 Software
: Switch on the machine and switch to the SITEST program.
: Deactivate the relevant nozzle changer under Gantries.
2
If you deactivate the nozzle changer, you will not be able to use the nozzle reject device. 2
Retrofit instructions: Besi JTF2 (Traystak feeder) SIPLACE S-25 HM / S-27 HM / HS-50 / HS-60 / HF-series / X-series
11/2006 Edition
58
2.11 Settings for the Traystak feeder
After installation 2
- the Traystak feeder must be initialized, 2
- the speeds and braking response must be set. 2
: To do this, read the user manual for the Besi Traystak feeder.
2.12 Possible causes of error
Adapter wobbles on the table 2
: Check that
- the adapter is seated firmly,
- whether the table is dirty,
- the screwed connection or clamp is correct.
2.13 Removing
: Reverse the sequence used for installation in order to remove.
2