00191986-02.pdf - 第15页
Retrofit Instructions Changeover Table S15-23, F3-F5, HS 50 Adapter Plate third Tape Reel 06/00 Issue 6 Function Test 15 )XQFWLRQ 7 HVW Å Check wh ether the tape reel holder c an be fitte d in all pos itions of the ad…

Adapter Plate third Tape Reel HS-50 Retrofit Instructions Changeover Table S15-23, F3-F5, HS50
5 Installing Adapter Plate 06/00 Issue
14
0RXQWLQJ$GDSWHU3ODWHRQ&KDQJHRYH U7DEOH
.H\
(1) Adapter plate (4) Socket head cap screw M8x25 (4x)
(2) Tape container (5) Housing
(3) Lug on carrier plate (6) Clamping strip (2x)
Å Place adapter plate (1) on tape container (2) such that lugs (Fig. 5 - 1, 7) of the carrier plates
rest on the tape container.
Å Fully push back the adapter plate such that the carrier plates rest on housing (5).
Å Insert clamping strips (6) in the feed table from behind and secure the clamping strips with sok-
ket head cap screws (4).
6
4
31-36
67-72
55-60
+30V
37-42
43-48
49-54
61-66
1-6
13-16
7-12
25-30
17-24
21
23
29
27
25
17
9
11
15
13
1
3
5
7
19
71
59
61
65
69
67
63
55
43
47
45
41
51
49
53
57
31
33
39
37
35
1
5
3
4
2

Retrofit Instructions Changeover Table S15-23, F3-F5, HS50 Adapter Plate third Tape Reel
06/00 Issue 6 Function Test
15
)XQFWLRQ7HVW
Å Check whether the tape reel holder can be fitted in all positions of the adapter plate.
The hook (Fig. 6 - 1, 1) must engage in the retaining spring (Fig. 5 - 1, 6)
.H\
(1) Hook
NOTE
Tape reel holders are not included in the scope of delivery of the adapter plate. Required quantities
are to be ordered separately.
Please note that one tape reel holder can accept two tape reels so that one tape reel holder is
required only for every second 3x8 mm feeder module.
Item No. 00141204-01 Reel holder 3X8 mm feeder version 2
1
Adapter Plate third Tape Reel HS-50 Retrofit Instructions Changeover Table S15-23, F3-F5, HS50
6 Function Test 06/00 Issue
16