Maintenance Tasks for Holding C ircuit Preparatory Steps 7.3.1 CPP: Cleaning/Checking the Holding Circuit 76 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 7.2 7 . 2 P r e p a r a t o r y S t e p s Prepa…

100%1 / 92
Maintenance Tasks for Holding Circuit
Tools, Consumables, Spare and Wear Parts
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 75
7
7 Maintenance Tasks for Holding Circuit
Maintenance Tasks for Holding Circuit
7.1
7.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
The following lists contain all necessary consumable materials, wear and spare parts plus tools for clean-
ing the holding circuit.
Consumables Item no. HMK
Lint-free cloth, KM wipe 03082092- xx
Ethanol
Isopropanol – IPA can be used as an alternative.
Distilled water
Compressed air
Protective latex gloves 00372972- xx
Anti-static plastic cleaner and care product (http://www.burnus.de)
Isopropanol – IPA can be used as an alternative.
Ultrasound cleaning agent Alsar 25NKF 03110147- xx
Wear parts Item no. HMK
CPP only:
Set of seals for holding circuit (for CPP and CP20x) 03095007- xx
Tools Item no. HMK
ESD wriststrap TYP.OK/WRS 00320279- xx
Multipipette (replaces: [03078989-xx]) 00386154- xx X
Combitips 10 µl orange 03109540- xx X
Ultrasound device
SIPLACE recommends that you use the following ultrasound device
and accessory parts from BANDELIN electronic (http://www.bande-
lin.com):
Ultrasound device SONOREX SUPER RK 510 [order no. Ban-
delin: 327]
Clip-on basket K 10 [order no. Bandelin: 359]
Handle adjustment GV 10 for baskets (one pair) [order no. Ban-
delin: 092]
Lid D 510 [order no. Bandelin: 3008]
Spare parts Item no. HMK
CPP only:
Holding circuit assembly for CPP version <= 04 03055424- xx
Holding circuit assembly for CPP version >= 05 03081381- xx
C&P20/A/M/P only:
Holding circuit assembly C&P20 03005123- xx
Maintenance Tasks for Holding Circuit
Preparatory Steps 7.3.1 CPP: Cleaning/Checking the Holding Circuit
76 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
7.2
7.2 Preparatory Steps
Preparatory Steps
Prepare the ultrasound bath.
7.3
7.3 Performing Maintenance Tasks
Performing Maintenance Tasks
7.3.1
7.3.1 CPP: Cleaning/Checking the Holding Circuit
CPP: Cleaning/Checking the Holding Circuit
CAUTION
Safety data sheet
Observe the safety data sheet for the cleaning fluid used.
NOTICE
Recommendation
We recommend that you have an additional holding circuit available, so that this can be easily
replaced during head maintenance.
Remove the sealing ring (1) and the sealing disk (2)
and clean them with a lint-free cleaning cloth. Check
the sealing ring and the sealing disk for damage and
replace them if necessary (set of seals for holding cir-
cuit/CPP [03095007-xx]).
Clean the holding circuit with a lint-free cleaning
cloth.
You can also use an anti-static plastic cleaner for bet-
ter cleaning results.
Maintenance Tasks for Holding Circuit
7.3.1 CPP: Cleaning/Checking the Holding Circuit Performing Maintenance Tasks
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 77
Fill ultrasound bath with a solution of 5 % cleaning medium Alsar 25 NKF and 95 % tap water. The
holding circuit must be completely covered by the fluid.
Set the ultrasound bath to 50° C.
Leave the holding circuit in the ultrasound bath for 30 min.
Take the holding circuit out of the ultrasound bath.
Blow through the holding circuit with compressed air.
Keep a distance of at least 1 cm to the holding circuit.
Make sure that the fluid is removed completely from the venturi nozzles.
Start with the outer holes.
Take care of the index pin.
Place the holding circuit into the ultrasound bath.
CAUTION!
If you are cleaning multiple holding circuits at the same
time, make sure that these do not touch one another in
the ultrasound bath.
CAUTION!
Neither put the screwed joint and the cover nor the seal-
ing ring and the sealing disk of the holding circuit into the
ultrasound bath.
CAUTION
Different cleaning liquids
DO NOT ever use the cleaning fluid which is used for the nozzles!
Rinse the holding circuit with distilled water.
To do this, fill the orange combitip with distilled water
and rinse each of the venturi nozzles from both sides.