00192328-01.pdf - 第51页
SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standa rd (Optionen) 02/01 Issue 2.2 Safety Instruc tions 49 'HILQLWLRQV DANGER in term s of th ese ins truct ions me ans th at dea …

2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.2 Safety Instructions 02/01 Issue
48
6DIHW\,QVWUXFWLRQV
DANGER
Only the Siemens service engineer is permitted to perform the retrofitting.
The Safety Instructions in chapter "Operational Safety" in the User Manual and in the Service
Manual S-25 HM take precedence.
The machines SIPLACE S-25 HM are powered by
120V / 208V +/- 5% (US version) or 3 x 230V/400V +/-5%, 50/ 60 Hz line voltage.
Portions of the system are therefore conducting dangerous electricity, inside the machine, even
while the master switch is turned off.
After you have properly carried out the shut-down of the Windows operating system NT:
BEFORE all work of retrofitting the machine must be turned OFF at the main switch and isolated
from the mains. In addition, the compressed air supply must be turned off at the main valve of the
compressed air unit in the machine base and the compressed air lines must be bled by actuating
the needle valve at the compressed air unit (particularly due to the risk of injury - posed by residual
air - at the pneumatic cutter after undocking/removing the component changeover table).
Obey the applicable accident prevention regulations, DIN standards and special safety codes of
your country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety".
Comply with regulations on ESDs (see Chapter "Operational Safety")
While installing the option RV6 -DLM1 head you are working in the gantry positioning range.
During the whole upgrade process secure the machine conscientiously against other personnel
and prevent it from being turned back on without authorization, as described in the User Manual
in the chapter "Locking the Machine...".
In additional, there is a higher risk of accident when working with the SITEST program.
The SITEST program is only to be started by personnel who are authorized to do so.
For the work with the SITEST program the component changeover table and the MTC (incl. com-
ponent table) must be moved in and correctly connected.

SIPLACE S-25 HM 2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen)
02/01 Issue 2.2 Safety Instructions
49
'HILQLWLRQV
DANGER
in terms of these instructions means that death, severe bodily injury or considerable material dam-
age WILL occur if the instructions about danger are not followed.
WARNING
in terms of these instructions means that death, severe bodily injury or considerable material dam-
age may occur if the warnings are not heeded.
CAUTION
in terms of these instructions mean that minor bodily injury or material may occur if the cautions
are not heeded.
NOTE
in terms of these instructions is a statement of important information about the product or the
pertinent portion of the instructions to which particular attention is being drawn.

2 Retrofitt. Instruct. RV6-DLM1 Head & Nozzle Chang. RV6 Standard (Optionen) SIPLACE S-25 HM
2.3 Retrofitting Kits, Tool and Documents 02/01 Issue
50
5HWURILWWLQJ.LWV7RRODQG'RFXPHQWV
&3KHDG5FRQILJXUDWLRQNLWRSWLRQ,WHPQR
-
Placement head assembly (RV 6-DLM1) Item no. 00354246-01 *)
- 3 Socket hex head cap screws M4 x 16 (to fasten the placement head)
- Head cover (re-use the screws previously removed) Item no. 00329003-01
- 12 Nozzles Item no. 00326123-02
- 12 Nozzles Item no. 00326124-02
- 1 enclosed package/DLM1_S23 Item no. 00345365-03
– 1 Adapter plate, enclosed package S23 Item no. 00354836-01
– 1 Extension hose, vacuum, holding circuit_S23 Item no.00350975-01
– 1 Extension hose, vacuum, placement circuit_S23 Item no.00351031-01
– 1 Extension hose, interrogation, placement circuit_S23 Item no.00351032-01
– 4 Rubber-metal vibration buffers M4,
15x30, 55 Shore D=15/H=30 Item no. 00345010-01
– 2 Velcro-type fastener Item no. 00346483-01
– 4 Cap screw M4x6 DIN6912 Item no. 00095105-01
– 4 Schnorr washer 4.3 V2a HN 160 Item no. 00342876-01
– 1 Conversion Instructions DLM1
Collect & Place Head S23/F5 G+E Item no: 00191684-0
- Retrofitting Instructions SIPLACE S-25 HM
RV6-DLM1 Head & Nozzle Changer RV6 Standard Item no. 00193123-01
*) The 2 wide ribbon cables and the ribbon cable to the illumination board of the RV12-DLM1
head that were de-installed are to be re-used for the RV6-DLM1 head.
1R]]OHFKDQJHUIRUVHJPHQWUHYROYHUKHDGRSWLRQ,WHPQR
This Option ist necessary for the RV6-DLM1 head (see also NOTE below).
NOTE:
If an MTC is installed
, the nozzle changer RV6 MTC for the 6-segment head is needed.
Proceed for installation, configuration and calibration of the nozzle changer RV6 MTC, as de-
scribed in the "Retrofitting Instructions MTC on S-25 HM", Item no. 00192792-02 (G + E).