00900170-01_ID_OIS_SIS_16.0_R18-2_EN_DE.pdf - 第24页
ASM OIS/SIS Datab ases 16.0 (R18 -2) / Interf ace Description 11/2018 Edition 24 4.5.1.18 CompBlock Table CompBlock OIS name Data type Byte CI I P Identification number of the station (reference to STATION table) lId int…

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
23
4.5.1.16 GantryState Table
The GantryState table reflects gantry state changes. The gantry states have been added to extend
the state transitions stored in STATETRANSITION table.
GantryState
OIS name
Data type
Byte
CI
I
P
Identification number of the station
(reference to STATION table))
lId
int
4
Number of gantry within the processing area
ucNumber
tinyint
1
Processing area 1 / 2
ucProcessingArea
tinyint
1
Gantry state value
sState
smallint
2
Error reason (is sState in Error state)
sErrorReason
smallint
2
BoardNumber of the board that has been
processed when the state change occurred.
lBoardNumber
int
4
Unique sequence id of the entry
lIdSequence
bigint
8
Date/time at which this event occurred.
Station time
dtTime
datetime
8
Definition of sState values
0:
Undefined
1:
Idle
2:
Interrupted
3:
Processing
4.5.1.17 PlocState Table
The PlocState table contains state changes related to the processing location. These states act as
extensions of the state changes related to the processing area that are stored in the
STATETRANSITION table.
PlocState
OIS name
Data type
Byte
CI
I
P
Identification number of the station
(reference to STATION table)
lId
int
4
Conveyor belt 1 → right / 2 → left
ucConveyor
tinyint
1
Processing area 1 / 2
ucProcessingArea
tinyint
1
PlocState state value
sState
smallint
2
Unique sequence id of the entry
lIdSequence
bigint
8
Date/time at which this event occurred.
Station time
dtTime
datetime
8
The definitions of the PlocStates (sState) are the same as those described in section 4.5.1.15.

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
24
4.5.1.18 CompBlock Table
CompBlock
OIS name
Data type
Byte
CI
I
P
Identification number of the station
(reference to STATION table)
lId
int
4
✓
Date/time at which the data record was created.
Station time
dtTime
datetime
8
✓
Serial number of manufactured PCB
lBoardNumber
int
4
Time when the data is written. Local server time
dtCreated
datetime
8
✓
Reference number of the entry.
lIdBlock
bigint
8
Unique number of the BoardComposite
lBoardCompositeId
bigint
8
4.5.1.19 CompDetail Table
CompDetail
OIS name
Data type
Byte
CI
I
P
Number of attempts to access this track
sAccessTotal
int
4
Sum of all reject attempts on this track after
Vision error messages
sRejectIdent
int
4
Sum of all reject attempts on this track after
other error messages
sRejectVacuum
int
4
Number of rejected parts because of ident error
sRejectIdent
smallint
2
Number of rejected parts because of vacuum
error
sRejectVacuum
smallint
2
Number of TrackEmpty pickup attempts
sTrackEmpty
int
4
Reference into CompBlock table
lIdBlock
bigint
8
✓
Reference into CompPosition table
lIdPosition
bigint
8
Number of successfully placed components on
this track
sPlacedComponents
int
4
Number of reject attempts on this track because
of missing components after pickup
sAbsenceAfterPick
int
4
Number of pickup attempts on this track
because of missing components before
placement
sAbsenceBefore
Placement
int
4
Number of rejects on this track because of
Coplan or material errors reported by Vision
sMaterialDefect
int
4
Number of rejects on this track because of
erroneous special procedures (dipping, gluing
etc.)
sTreatmentError
int
4
Number of rejects on this track because of an
interrupted placement process (i.e. canceled
board)
sDroppedError
int
4
Number of rejects on this track because of
pickup tolerances checked by Vision
sIdentError
int
4
Number of (incorrect) placement attempts on
this track because of gluey components
sPresenceAfter
Placement
int
4

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
25
Number of consecutive pickup attempts that
does not cause an track-empty error.
sPickupRetries
int
4
Version of the information source for the reject
data
sAttritionInfoVersion
int
4
Definition of sRejectVacuum
sRejectVacuum = SUM(sAbsenceAfterPick, sComponentAbsenceBeforePlacement,
sTreatmentError, sDroppedError, sComponentAbsenceAfterPlacement,
sPickupRetries)
Definition of sRejectIdent
sRejectIdent = SUM(sComponentMaterialDefect, sIdentError)
Definition of sPlacedComponents values
-1:
Undefined for all data records issued by a station with a station software version < 708
0:
No successful placement (i. e. pass-through mode, canceled board etc.)
n:
n successful placements
Definition of sAttritionInfoVersion values
0:
Reject data comes from a station software version < 708
1: