ASM OIS/SIS Datab ases 16.0 (R18 -2) / Interf ace Description 11/2018 Edition 68 21812 Component inspection failed 21813 Size check failed 21815 Flipped component detected 21816 Quality is too low for optical centering 2…

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
67
3573
Nozzle dirty or obstruction during pickup
3575
Warning: Early vaccuum setting not enabled
13005
Coplanarity module: Component faulty
15265
Cover foil on tape feeder damaged
15266
Cover foil not removed from tape feeder
17410
Coplanarity module: Component faulty
18109
Cover foil on tape feeder damaged
18132
Cover foil not removed from tape feeder
18133
Coplanarity module: Component faulty
18134
Cover foil on tape feeder damaged
18135
Cover foil not removed from tape feeder
18136
Nozzle worn
18137
Track empty error detected by component sensor
18138
Nozzle missing
18139
Nozzle soiled before pick-up
18509
Vacuum not achieved (no component on the nozzle)
18510
Vacuum not achieved (component not located securely on the nozzle)
18517
The difference between open and closed vacuum values is too small
18554
Component not at nozzle after pick-up
18555
Component not on nozzle prior to placement
18557
Nozzle not empty prior to pick-up
18558
Nozzle not empty after placement
18560
Error in feeder on pick-up
18565
Component not at nozzle after pick-up
18566
Component not at nozzle before placement
18567
Component not on nozzle during dipping
18570
Component not on nozzle prior to dipping
18916
Component cannot be picked up with the selected head type
18921
(Bauelement wird abgeholt bevor die Abholposition erreicht wird)
19112
Component not seated on nozzle correctly on pickup
21017
Component picked up at wrong angle
21424
Component description for measurement with SIPLACE Vision incomplete
21802
Component outside feed tolerance
21803
Component rotation angle outside tolerance
21804
Measured offset in X and Y outside presentation tolerance
21805
Measured offset in X outside presentation tolerance
21806
Measured offset in Y outside presentation tolerance
21808
Measured blob area outside tolerance
21811
Position cannot be determined

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
68
21812
Component inspection failed
21813
Size check failed
21815
Flipped component detected
21816
Quality is too low for optical centering
21817
No component in front of the camera or component not bright enough
21821
Flipped component detected
21822
Quality is too low for optical centering
21823
No component in front of the camera or component not bright enough
21826
Position (approcimate) cannot be determined
21827
Angle (approcimate) cannot be determined
21828
Position (fine) cannot be determined
21831
Not all features of the component were detected
21832
Not all ball features of the component were detected
21833
Features outside positional tolerance
21834
Ball features outside positional tolerance
21838
Component hat not been dipped in flux correctly
21841
Nozzle is soiled
21842
Nozzle duct blocked
21843
Nozzle wom
21880
Measurement with 3D sensor failed
21881
Measurement with 3D sensor: Not all connections were found
21882
Measurement with 3D sensor: At least one connection is damaged
21883
Measurement with 3D sensor: Coplanarity outside tolerance
21884
Measurement with 3D sensor: Distance between component and sensor too
small
21885
Measurement with 3D sensor: Distance between component and sensor too
large
21886
Measurement with 3D sensor: Component tilted too much
22001
X-Feeder: Component was not transported into specified position in the
defined time.
22002
X-Feeder: Component was not transported into specified position in the
defined time.
22004
X-Feeder: Foil tom
22005
X-Feeder: Foil removal incorrect
22006
X-Feeder: Foil removal device blocked
22015
X-Feeder: Feeder not mounted or communication to feeder interrupted.
22017
X-Feeder: Tape drive of the feeder is not referenced
22018
X-Feeder: Low foil tension
22023
Attempt to access track without component tape
30460
Unspecific axis hardware error

ASM OIS/SIS Databases 16.0 (R18-2) / Interface Description 11/2018 Edition
69
30475
Z Axis, component at nozzle missing
30476
Z Axis, component at nozzle although no component expected
30477
Z Axis, component too small
30478
Z Axis, component too large
30622
Nozzle missing
30700
Error moving Z axis down
30701
Error moving Z axis up
30744
Component cannot be placed because skinning time has expired
30749
High component is on the nozzle
30750
Nozzle was not properly engaged when picking up nozzle
30780
Component present on nozzle before pickup
30781
Component not present on nozzle after pickup
30782
Component not present on nozzle before placement
30783
Component still present on nozzle after placement
30784
Component not present before dipping
30785
Component not present after dipping
30786
Component not present on nozzle before rejection
30787
Component still present on nozzle after rejection
30788
Component not present on nozzle before recycling
30789
Component still present on nozzle after recycling
30794
Placement aborted. The component has not touched the board
31830
Cannot pick up component
31831
Vision error occurred
31834
Component height measurement failed
31837
Foil torn. Machine was stopped to protect Z axis
33211
Measurement result has bad quality
33214
Cannot measure component. Please change to component teaching gui
33325
Field of view of camera is too small for measurement
33326
One feature is too small for measurement with SIPLACE Vision
33333
3D sensor: Components of this type cannot be measured
33334
3D sensor: Gull wing and ball connections cannot be measured
simultaneously
33335
3D sensor: Too few connections for measurement with the 3D sensor
33338
SIPLACE Vision scaling outside tolerance
33340
Component rotation angle outside tolerance
33341
Measured offset in X and Y outside feed tolerance
33342
Measured offset in X outside feed tolerance
33343
Measured offset in Y outside feed tolerance
33344
Measured lead length outside tolerance