00196429-0102 - AI Head Reconfiguration Kit SX12 C&P20A_de_en.pdf - 第40页
Introduction Abbreviations Safety Instructions for the Gantry 40 Assembly Instructions / Mont ageanleitung Head Reconfiguratio n Kit C&P20A Abbreviat ions 1.3 Abbreviations Abbreviations Description PA Placement ar e…
Introduction
Safety Instructions for the Gantry Preparatory Work...
Assembly Instructions / Montageanleitung Head Reconfiguration Kit C&P20A 39
employees that the machine is de-energized for servicing. The tag or label must be securely fas-
tened, it must be placed in a position visible to all and it may only be removed by the person who
attached it.
► Release of stored energy
Stored energy in the compressed air supply or electrical energy in electrolytic capacitors must be
released by appropriate means.
⇨ After switching off the machine, wait until the voltages and the compressed air have discharged,
so that work can be performed without any risk.
► Testing the lock out.
Testing the lock out can be done simply by pressing the start button.
► The following steps must be taken to restore the machine to operation.
► Check the working area. Authorized employees should remove all of their tools and reinstall all safety
features.
► Notify all affected employees.
► Before removing even one lock or tag, inform all workers in the affected area that the machine is
going to be restarted.
► Remove locks/tags
► Every authorized employee must remove his own lock and shut it away.
► Turn the machine on. Make sure that authorized staff check the equipment in operation to ensure
that repairs were done correctly
Testing
Service personnel may test circuits by energizing them briefly without suspending the Lock Out / Tag
Out Procedure. This may only be done when no other work is being performed by any other person on
the equipment being tested.
It is extremely important that all remote start switches be tagged with the "Do Not Operate" tag to prevent
inadvertent operation of the equipment during these periods.
Responsibilities
▪ It shall be the responsibility of the maintenance and service personnel to make sure this procedure
is adhered to.
▪ It shall be the responsibility of the maintenance and service personnel's immediate supervisor to in-
struct his personnel on this procedure.
▪ It shall be the responsibility of the Safety Officer with assistance from the Safety Committee, Health
Service Department, and the various managers and vice-presidents to administer the Lock Out / Tag
Out Procedure.

Introduction
Abbreviations Safety Instructions for the Gantry
40 Assembly Instructions / Montageanleitung Head Reconfiguration Kit C&P20A
Abbreviations
1.3 Abbreviations
Abbreviations Description
PA Placement area
CO Component
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P6, CP6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP12 and/or CP6
DC Dual conveyor with 2 lanes
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
SC Single conveyor with 1 lane
FHE Fast Head Exchange
PCB Printed circuit board
P&P Pick&Place
QC Quad lane conveyor with 4 lanes
SCS Single Core Solution
SC Station computer
TH TwinHead
VS Vision system
WPC Wafflepack Changer
WPC4 Waffle Pack Changer Version 4
WPC5 Wafflepack Changer Version 5
WPC6 Waffle Pack Changer Version 6

Brief Description
Reconfiguration Kit C&P20A SX1/2 [00519982-xx] Scope of Delivery
Assembly Instructions / Montageanleitung Head Reconfiguration Kit C&P20A 41
Brief Description
2 Brief Description
Scope of Delivery
2.1 Scope of Delivery
▪ C&P20A Head Reconfiguration Kit SX1/2 [00519982--xx]
▪ Placement head C&P20A [03062095--xx]
▪ When replacing a TwinHead by a C&P20A head:
Additional parts set for TwinHead to CPx
Reconfiguration Kit C&P20A SX1/2 [00519982-xx]
2.1.1 Reconfiguration Kit C&P20A SX1/2 [00519982-xx]
Additional Parts Set TwinHead t o CPx
2.1.2 Additional Parts Set TwinHead to CPx
1 x 00196429-xx Assembly Instructions Head Reconfiguration Kit C&P20, SX1/2
1 x 03063095-xx Placement head C&P20A with camera
1 x 030832928
includes
Parts set CPP to CP20
8 x 03042541-xx ISO 4762 - M 3 x 6-A2-70
2 x 03069093-xx ISO 4762 - M 3 x 50-8.8, zinc, TFP
1 x 03065867-xx Flat cable set C+P20 / B series
1 x 03065869-xx
includes
Piping C+P20 / B series
1 x 03016216-xx Hose / Pressure control valve C+P20
1 x 03070202-xx ESD tube / holding circle C+P20
1 x 03052349-xx L press-fit connection with push-on socket QSL12H
2 x 00330249-xx Plug QSC-4H
2 x 00337891-xx Plug QSC-6H
2 x 03084178-xx
includes
Coding sheet cplt.
1 x 03083883-xx Coding sheet box
2 x 03042552-xx ISO 4762 - M 4 x 10-A2-70
1 x 03055516-xx PCB / B-Base adapter C+P
8 x 03042541-xx ISO 4762 - M 3 x 6-A2-70
2 x 03069093-xx ISO 4762 - M 3 x 50-8.8, zinc, TFP
1 x 03048638-xx Bin
4 x 03062378-xx Component reject bin up to 6x6 f. P001
1 x 03073328-xx Nozzle station CPx cplt. / X, B Series
3 x 030395514-xx Shim plate for nozzle reject device
1 x
includes:
03051467-xx Piping of nozzle station / with valve
1 x 03055785-xx Valve for nozzle station cplt.
2 x 00350291-xx DIN912-M2.5 x 16-A2-70
1 x 03055792-xx Press-fit connection with push-on socket QSY-6H-4
1 x 00330249-xx Plug QSC-4H
1 x 03056097-xx PUN-CM 4x0.75 / 135mm
1 x 03056096-xx PUN-CM 4x0.75 / 200mm