Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 8/18
6. Procedure flow
The following diagram shows the procedure flow from upgrade to completion of
production when using the hybrid calibration offset measurement function. Refer to the
individual chapters for details.
Perform version upgrade
Confirm the settings in Accessory
Software (“4. Enabling hybrid calibration
offset measurement”)
Perform hybrid calibration measurement
In case of error:
“8. Troubleshooting errors that occur
during hybrid calibration measurement”
Perform changeover
Perform hybrid calibration offset
Perform autocalibration
Perform production
Position the jig nozzles (“7. Performing
changeover”)
Transmit the job

Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 9/18
7. Performing changeover
7.1. Performing changeover for hybrid calibration measurement
The following explains how to perform changeover for hybrid calibration
measurement.
Set the jig nozzles in the nozzle station as shown below.
NXT-2 operation panel NXT-3 operation panel
Jig nozzles that can be used (nozzles IDs are given)
Head type
Machine condition
H01,
H02(F)
G04(F)
H12S,
H12HS,
H08
H12L
H04,
H04S(F
)
V12D,
H24
OF DX(S1) DX(R4) DX(R12)
φ5.0 jig nozzle for glass
jig parts
J11 J13 - - J17 - J21 J60 J39 -
φ1.3 jig nozzles for chip
jig parts
J12 J14 J16 J63 J18 J44 - J59 J41 J16
Ÿ Dedicated jig nozzles are required for hybrid calibration measurement. It is
necessary to combine these with the normal jig nozzles used for
autocalibration.
Ÿ The number of dedicated hybrid calibration jig nozzles does not depend on the
number of holders on the head. Instead, one nozzle is required for each of the
jig parts.

Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 10/18
7.2. Using an H02(F) head with an NC03B nozzle station
When using an H02 head with an NC03B nozzle station, the dedicated hybrid
calibration jig nozzles cannot be set at the same time as the normal autocalibration
jig nozzles, due to the number of sockets in the nozzle station. When the (two) hybrid
calibration jig nozzles plus the number of holders on the head being used is greater
than the number of sockets on the nozzle station, guidance for the positioning of jig
nozzles is performed in two stages - immediately before calibration that uses the
normal jig nozzles and immediately before hybrid calibration measurement.
Perform changeover
(normal jig nozzle positioning guidance)
Autocalibration is performed using
normal jig nozzles
Position normal jig nozzles
Hybrid calibration is performed using
hybrid calibration jig nozzles
Perform changeover
(hybrid calibration jig nozzle positioning
guidance)
Position hybrid calibration jig nozzles
Perform changeover if necessary
(positioning guidance for nozzles used in
production)
Position nozzles to be used in
production
Perform production