Chapter 4 V ision Processing Errors Part 6 Error Code 1C410129 Cause: T raining cannot be carried out because the coarse edge is not correct. Remedy: Check the generic device description. Error Code 1C410130 Cause: The c…

Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C410122
Cause: There is no coarse edge.
Remedy: When the frontlight is being used a coarse edge is necessary.
Check the generic device description.
Error Code 1C410123
Cause: Pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410124
Cause: Pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410125
Cause: A preset time limit has been exceeded.
Error Code 1C410126
Cause: Even though coarse edge was performed, the pick-up tolerance
is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410127
Cause: Coarse edge was not found.
Error Code 1C410128
Cause: Training cannot be carried out because the pickup tolerance is
too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
6 – 22Version 2.0

Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C410129
Cause: Training cannot be carried out because the coarse edge is not
correct.
Remedy: Check the generic device description.
Error Code 1C410130
Cause: The coarse edge pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410131
Cause: The coarse edge pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410132
Cause: The blob cannot be seen from the nozzle position.
Error Code 1C410133
Cause: Blob inspection error due to faulty device rotation angle setting.
Error Code 1C410134
Cause: There is insufficient data in the generic device description.
Remedy: Check the generic device description. This error should never
occur.
Error Code 1C410143
Cause: Caliper window does not fit correctly.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
6 – 23Version 2.0

Chapter 4 Vision Processing ErrorsPart 6
4.4 Vision Processing System Errors
Error Code 1C420002
Cause: A command in the vision processing system is incorrect.
Remedy: If this error occurs contact Fuji.
Error Code 1C420004
Cause: A command in the vision processing system is incorrect.
Remedy: If this error occurs contact Fuji.
Error Code 1C420007
Cause: A command in the vision processing system is incorrect.
Remedy: If this error occurs contact Fuji.
Error Code 1C420009
Cause: There is a communication error with the vision processing
system.
Remedy: If this error occurs contact Fuji.
Error Code 1C420010 ~ 1C420013
Cause: A command in the vision processing system is incorrect.
Remedy: If this error occurs contact Fuji.
Error Code 1C420014
Cause: There is a communication error with the vision processing
system.
Remedy: If this error occurs contact Fuji.
Error Code 1C420015
Cause: An error occurred during file forwarding. It is possible that the
system program or the data could be damaged.
Remedy: If this error occurs contact Fuji.
6 – 24Version 2.0