00192156-04.pdf - 第46页
Maintenance Maintenance Instr uctions F 8 2-monthly maintenance work 03/2003 US E dition 46 8 2-monthly maintenance work 8

Maintenance Instructions F Maintenance
03/2003 US Edition 7 Monthly maintenance work
45
a Oil and preserve the linear guides using a fresh SIPLACE cleaning cloth.
: Replace the guard over the cutter.
7
s Use a lint-free cloth dipped in ethyl alcohol to clean the contact surfaces, both inside the ma-
chine and on the changeover table.
: Preserve the contact surfaces using a lint-free cloth sprayed with WD40.
7
7
: Reverse the order described above to return the changeover table to the machine.
Make sure that the locating pins on the changeover table holders slide into their holes in the
changeover table.
7
: Fix the changeover table in position using the tensioners and socket-head cap screws, then
connect up the machine again in the following order:
1. Compressed air supply for the bulk case feeder
2. Rectangular data connector
3. Round main power plug.
7
7
: Close the protective hood.
: Repeat these tasks in all the feeder areas.
: Switch the placement machine on at the main switch.
7
7
7
7
7
7
7

Maintenance Maintenance Instructions F
8 2-monthly maintenance work 03/2003 US Edition
46
8 2-monthly maintenance work
8

Maintenance Instructions F Maintenance
03/2003 US Edition 8 2-monthly maintenance work
47
8
You will need the following tools, equipment and consumables for the 2-monthly maintenance. 8
– Vacuum cleaner
– Condensate drip tray
– Short-bristled brush
– Phillips screwdriver
– Set of hexagon socket spanners
– Nozzle removal tool (article no. 00311448-01)
– Whetstone / oilstone
–Scissors
– Lint-free cloths
– SIPLACE cleaning tissue (article no.: 00315253-02)
– ISOFLEX TOPAS NCA52 grease (article no. 00328369-01)
– WD40 (article no.00325833-01)
– If necessary, diaphragms for 418 (article no. 00307052-03)
and 419 nozzles (article no. 00310569-03)
– If necessary, filter insert, 5 microm. for series 112
F4 / F5 / F5HM (article no. 00355386-01)
F3 / F4 Old (article no. 00330406-01)
– New silencer for the Collect & Place head, if necessary (from article no. 00320964-01).
– If necessary, new vacuum generator for the Pick&Place head (article no. from 00305378-01).
8
8
Inspect or replace the filter cartridge 8
a Open the door to the compressed air supply.
s Place a drip tray beneath the compressed air maintenance unit.
: Close the main compressed air valve.
d Once both manometers read 0, switch the placement machine off at the main switch.