ASM-SX-V3-设备性能参数-DMS.pdf - 第45页

45 Technical data Electrical connection and compressed air 1 = Electrical connection 2 = Compressed air connection The connections are run into the machine from below and then co nnected to the power supply of pneumatic …

100%1 / 62
44
Technical data
Compressed air supply
Compressed air supply
Compressed air pres-
sure values
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air con-
nection
1/2" hose connection
Compressed air consumption
a
a) Average consumption values. Under normal atmospheric conditions at 20°C and 1013 hPa.
Placement head con-
figuration
Compressed air
consumption
with vacuum pumpd
b
b) Vacuum pump for C&P20 P2 P head only (optional).
Compressed air consumption
without vacuum pump
c
c) Standard
SIPLACE SX2 C&P20 P2 /C&P20 P2
CPP / CPP
CPP / TH
TH / TH
200 Nl/min
--
--
--
490 Nl/min
240 Nl/min
240 Nl/min
200 Nl/min
SIPLACE SX1 C&P20 P2
CPP
TH
100 Nl/min
--
--
280 Nl/min
140 Nl/min
100 Nl/min
Compressed air specification according to ISO 8573
Particle size (ISO class 3) 5 µm
Particle density (ISO class 3) 5 mg/m³
Maximum oil content
(ISO class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4) Dewpoint + 3°
45
Technical data
Electrical connection and compressed air
1 = Electrical connection
2 = Compressed air connection
The connections are run into the machine from below and then connected to the power
supply of pneumatic unit.
PLEASE NOTE:
Also observe the document "Network and compressed air configuration for SMD systems" (Ger-
man+English, item no. 00197548-xx), which is provided with delivery of SIPLACE machines.
46
Technical data
Dimensions and setup conditions
Machine length
With input conveyor extension
1500 mm
1760 mm
Machine width
a
Over the two docked component trolleys and bottom handles
With monitor and keyboard
b
a) 1 component trolley inside and 1 component trolley outside with handles folded down.
b) Optional
2475 mm
2854 mm
Height of the machine
with indicator lamp
with folded-up protective covers
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
max. 1765 mm
1980 mm
2010 mm
2030 mm
Machine ground clearance
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
120 mm ± 15 mm
150 mm ± 15 mm
170 mm ± 15 mm
Weight
c
SX1 with 2x component trolley 60
SX1 with 2x component trolley 60 (fully configured)
SX2 with 2x component trolley 60
SX2 with 2x component trolley 60 (fully configured)
c) 1 component trolley inside, 1 component trolley outside and single conveyor.
2482 kg
2806 kg
2532 kg
2856 kg
Location
a
SIPLACE SX1/SX2 with 2x component trolley 60 3.71 m²
Load per unit area
b
The load per unit area calculation included an additional working
space of 0.5 m on each side of the machine.
SIPLACE SX1
SIPLACE SX2
6.1 kN/m²
6.2 kN/m²
Load per unit area
b
The load per unit area calculation includes an additional working
space of 1.0 m on each side of the machine.
SIPLACE SX1
SIPLACE SX2
4.7 kN/m²
4.8 kN/m²
Number of machine feet 4
Max. noise emissions 75 dB (A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75% (no higher than 45% on average
to prevent any possibility of condensation on
the machine)