plug-play-automatic-feed-soldering-jbc-0033471_ID-245332_EN.pdf - 第9页
Lan gu ag e F eeder se ngs St a on se ngs T oo l se n gs Coun t er s R ese t Tin r eload p r ocess Tin r elo ad p r o cess Mo d e Co n nuous 5.0mm/ s 1.00mm On On Speed Wir e d iame t er F eed er par ame t er s lo…

Language
Feeder sengs
Staon sengs
Tool sengs
Counters
Reset
Tin reload process
Tin reload process
Mode
Connuous
5.0mm/s
1.00mm
On
On
Speed
Wire diameter
Feeder parameters lock
Wire clogging detecon
None
Backward
Back
Tin reload process
Forward
Backward
Place the n on the gears
and press:
Press ok to exit
Program
Connuous
Disconnuous
Mode
Back
0.5
mm/s
25%
75%
Power
Connuous
50%
19:29
Sel. Temp.
350
º
C
Ø 1.00 mm
Supplied: 0 mm
350
º
C
0.5
10.0
25%
75%
Power
Disconnuous
50%
19:29
Sel. Temp.
350
º
C
Ø 1.00 mm
350
º
C
mm/s
mm
25%
75%
Power
50%
19:29
Sel. Temp.
350
º
C
350
º
C
3
2
1
Program #1
Ø 1.00 mm
Feeder parameters lock
None
On
On
Edit program
Programs loaded
Set default programs
Backward
1.00mm
Wire diameter
Wire clogging detecon
Back
Mode
Program
Edit program
Program #1
Length
Speed
3
2
1
mm
1.0
5.0
5.0
5.0
2.0
2.0
mm/s
Edit program
Length
Speed
3
2
1
mm
None
None
None
None
2.0
2.5
mm/s
Program #4
Tin reload process
Staon sengs
Counters
Language
Reset
Tool sengs
Feeder sengs
English
Deutsch
Español
Italiano
Français
日本語
한국어
Português
Pусский
Program version
8886732
Maximum temp
400
º
C
Off
200
º
C
On
º
C
mm
Minimum temp
Sound
PIN
Temp units
Length units
Staon reset
Back
Temp adjust
0
º
C
Temp level set
Off
10min
0min
150
º
C
Sleep delay
Peripher.
Sleep temp
Hibernaon delay
Back
Plug hrs
28
Working hrs
Part
Tot
6
0
0
0
20
1
2
1
24
20
181
19
22786
118
Sleep hrs
Sleep cyc
Fed cyc
Fed mm
Hiber hrs
No tools hrs
Feeder parameters lock
20.0mm/s
None
1.00mm
12.0mm
On
On
Speed
Wire diameter
Length
Backward
Wire clogging detecon
Back
Mode
Disconnuous
Mode
Connuous
5.0mm/s
1.00mm
Off
None
Speed
Wire diameter
Feeder parameters lock
Backward
On
Wire clogging detecon
Back
325
º
C
24.0
mm/s
25%
75%
Power
Connuous
50%
Sel. temp. 325
º
C
Ø 1.00 mm
Supplied: 12 mm
1.00mm
Updang
Your staons is being updated
No
Do you want to update firmware?
Yes
Language
Feeder sengs
Staon sengs
Tool sengs
Counters
Reset
Tin reload process
EARTH FUSE F1.25 A
USE ONLY WITH A 250 V FUSE
EARTH FUSE F1.25 A
EARTH FUSE F1.25 A
USE ONLY WITH A 250 V FUSE
EARTH FUSE F1.25 A
ALE250
ALE250
ALE250
3
1
2
4
5
1
2
1
8
Solder Wire Feeding
Inlet
Nozzle
Solder Wire
Guidance
Wheels
Select “Tin Reloaded Process” (1) and then press and hold to
feed the solder wire and advance until it comes out through the
outlet nozzle.
If needed, carefully push the wire until it gets locked in between the
rotating wheels for the wire to start moving forward.
Keep pressed and after a while the wire will advance faster.
Make sure that the solder wire passes through the solder wire guidance
(1). Introduce the solder wire into the inlet nozzle (2) until it reaches
the wheels (3).
Make sure the wire passes through the intermediate nozzle (4) and
enters the guide tube (5).
Guide
Tube
Intermediate
Nozzle
Solder
Wire
Solder Wire
Inlet
Solder Wire
Outlet
Step 8 Solder Wire Loading
Dragging Buttons
Outlet Nozzle
Forward the solder wire pushing any of the two dragging buttons (1)
until the wire comes out of the outlet nozzle (2).
More convenient handling thanks to its two dragging buttons
The component layout or application angle may require working
in different positions. Having one button on each side of the tool
increases adaptability and makes it easier to reach difficult solder
joints without compromising user comfort.
Solder Wire Feeding
Alternatively, solder wire can also be fed using pedal P405. The pedal
should be plugged in at the rear of the feeder control unit into the
pedal connector.
Working with Pedal

Language
Feeder sengs
Staon sengs
Tool sengs
Counters
Reset
Tin reload process
Tin reload process
Mode
Connuous
5.0mm/s
1.00mm
On
On
Speed
Wire diameter
Feeder parameters lock
Wire clogging detecon
None
Backward
Back
Tin reload process
Forward
Backward
Place the n on the gears
and press:
Press ok to exit
Program
Connuous
Disconnuous
Mode
Back
0.5
mm/s
25%
75%
Power
Connuous
50%
19:29
Sel. Temp.
350
º
C
Ø 1.00 mm
Supplied: 0 mm
350
º
C
0.5
10.0
25%
75%
Power
Disconnuous
50%
19:29
Sel. Temp.
350
º
C
Ø 1.00 mm
350
º
C
mm/s
mm
25%
75%
Power
50%
19:29
Sel. Temp.
350
º
C
350
º
C
3
2
1
Program #1
Ø 1.00 mm
Feeder parameters lock
None
On
On
Edit program
Programs loaded
Set default programs
Backward
1.00mm
Wire diameter
Wire clogging detecon
Back
Mode
Program
Edit program
Program #1
Length
Speed
3
2
1
mm
1.0
5.0
5.0
5.0
2.0
2.0
mm/s
Edit program
Length
Speed
3
2
1
mm
None
None
None
None
2.0
2.5
mm/s
Program #4
Tin reload process
Staon sengs
Counters
Language
Reset
Tool sengs
Feeder sengs
English
Deutsch
Español
Italiano
Français
日本語
한국어
Português
Pусский
Program version
8886732
Maximum temp
400
º
C
Off
200
º
C
On
º
C
mm
Minimum temp
Sound
PIN
Temp units
Length units
Staon reset
Back
Temp adjust
0
º
C
Temp level set
Off
10min
0min
150
º
C
Sleep delay
Peripher.
Sleep temp
Hibernaon delay
Back
Plug hrs
28
Working hrs
Part
Tot
6
0
0
0
20
1
2
1
24
20
181
19
22786
118
Sleep hrs
Sleep cyc
Fed cyc
Fed mm
Hiber hrs
No tools hrs
Feeder parameters lock
20.0mm/s
None
1.00mm
12.0mm
On
On
Speed
Wire diameter
Length
Backward
Wire clogging detecon
Back
Mode
Disconnuous
Mode
Connuous
5.0mm/s
1.00mm
Off
None
Speed
Wire diameter
Feeder parameters lock
Backward
On
Wire clogging detecon
Back
325
º
C
24.0
mm/s
25%
75%
Power
Connuous
50%
Sel. temp. 325
º
C
Ø 1.00 mm
Supplied: 12 mm
1.00mm
Updang
Your staons is being updated
No
Do you want to update firmware?
Yes
Language
Feeder sengs
Staon sengs
Tool sengs
Counters
Reset
Tin reload process
Language
Feeder sengs
Staon sengs
Tool sengs
Counters
Reset
Tin reload process
Tin reload process
Mode
Connuous
5.0mm/s
1.00mm
On
On
Speed
Wire diameter
Feeder parameters lock
Wire clogging detecon
None
Backward
Back
Tin reload process
Forward
Backward
Place the n on the gears
and press:
Press ok to exit
Program
Connuous
Disconnuous
Mode
Back
0.5
mm/s
25%
75%
Power
Connuous
50%
19:29
Sel. Temp.
350
º
C
Ø 1.00 mm
Supplied: 0 mm
350
º
C
0.5
10.0
25%
75%
Power
Disconnuous
50%
19:29
Sel. Temp.
350
º
C
Ø 1.00 mm
350
º
C
mm/s
mm
25%
75%
Power
50%
19:29
Sel. Temp.
350
º
C
350
º
C
3
2
1
Program #1
Ø 1.00 mm
Feeder parameters lock
None
On
On
Edit program
Programs loaded
Set default programs
Backward
1.00mm
Wire diameter
Wire clogging detecon
Back
Mode
Program
Edit program
Program #1
Length
Speed
3
2
1
mm
1.0
5.0
5.0
5.0
2.0
2.0
mm/s
Edit program
Length
Speed
3
2
1
mm
None
None
None
None
2.0
2.5
mm/s
Program #4
Tin reload process
Staon sengs
Counters
Language
Reset
Tool sengs
Feeder sengs
English
Deutsch
Español
Italiano
Français
日本語
한국어
Português
Pусский
Program version
8886732
Maximum temp
400
º
C
Off
200
º
C
On
º
C
mm
Minimum temp
Sound
PIN
Temp units
Length units
Staon reset
Back
Temp adjust
0
º
C
Temp level set
Off
10min
0min
150
º
C
Sleep delay
Peripher.
Sleep temp
Hibernaon delay
Back
Plug hrs
28
Working hrs
Part
Tot
6
0
0
0
20
1
2
1
24
20
181
19
22786
118
Sleep hrs
Sleep cyc
Fed cyc
Fed mm
Hiber hrs
No tools hrs
Feeder parameters lock
20.0mm/s
None
1.00mm
12.0mm
On
On
Speed
Wire diameter
Length
Backward
Wire clogging detecon
Back
Mode
Disconnuous
Mode
Connuous
5.0mm/s
1.00mm
Off
None
Speed
Wire diameter
Feeder parameters lock
Backward
On
Wire clogging detecon
Back
325
º
C
24.0
mm/s
25%
75%
Power
Connuous
50%
Sel. temp. 325
º
C
Ø 1.00 mm
Supplied: 12 mm
1.00mm
Updang
Your staons is being updated
No
Do you want to update firmware?
Yes
Language
Feeder sengs
Staon sengs
Tool sengs
Counters
Reset
Tin reload process
EARTH FUSE F1.25 A
USE ONLY WITH A 250 V FUSE
EARTH FUSE F1.25 A
EARTH FUSE F1.25 A
USE ONLY WITH A 250 V FUSE
EARTH FUSE F1.25 A
1
9
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - negro plano
200 mm
300 mm
Feeder Setting Modes
Depending on the selected mode, different parameters are
available for “Feeder Settings”.
Choose between “continuous”, “discontinuous” and “program”
mode. Access to Main Menu by pressing , select “Feeder
Settings” (1) and then “Mode” (2). For more details see ALE control
Unit Manual or JBC Web www.jbctools.com/auto-feed-stations.
html
Inlet Nozzle
Wire Guidance
Solder Wire
Wire Winding Direction
Solder Reel
With Solder Wire Perforation
To unload perforated solder wire that has already passed through
the guide tube, cut the wire between the wire guidance and the
inlet nozzle (1).
To extract the wire out of the tool and the guide tube, hold the tool
on your hand and press until the wire stops moving forward.
Grasp the wire coming out of the outlet nozzle with a pliers and pull
from it until it is completely out.
Without Solder Wire Perforation
When using a kit without solder wire perforation, press
until the wire is completely wound to unload the solder wire.
It is best to rotate the reel by hand as the wire is being pulled back
in order to keep it neatly arranged on the reel.
Or, if preferred, proceed as described above for perforated solder
wire unloading.
Step 9 Solder Wire Unloading
Step 9 Control Process
Access to ALE control unit
product page
ALE control unit instruction
manual can be downloaded
from the product page
accessible via this QR code.

Notes
10