00197902-03_UM_X-Serie-S_EN.pdf - 第257页

User manual SIPLACE X-Series 5 Working with the machine From software version 710.0 Edition 12/2016 5.3 Switching on the SIPLACE line 257 5.3 Switching on the SIPLACE line 5.3.1 St arting the SIPLACE Pr o Line Control GU…

100%1 / 416
5 Working with the machine User manual SIPLACE X-Series
5.2 Controls and displays From software version 710.0 Edition 12/2016
256
5.2.3 Ergonomic arrangement of controls
Fig. 5.2 - 1, page 253 provides an overview of the position of the controls. They are subdivided
into the following groups:
Operator panel at location 1 5
LCD touchscreen
Keyboard with trackball
Start button
Stop button
Main switch
Operator panel at location 2 5
LCD touchscreen
Keyboard with trackball
Start button
Stop button
5.2.3.1 Controls on the machine's operator panels
The two operator panel have identical control functions.
Monitor, keyboard, start and stop buttons 5
There is a monitor and a keyboard on both sides of the machine.
The start and stop buttons are located beneath the keyboard. The on-screen dialog will occasion-
ally prompt you to activate certain actions using buttons, and this arrangement will make it easier
for you both to activate and to interactively control these actions.
Main switch 5
The main power switch is part of the power module. It is located here because it is only needed
for servicing and preventive maintenance work and is therefore not subject to frequent use.
User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.3 Switching on the SIPLACE line
257
5.3 Switching on the SIPLACE line
5.3.1 Starting the SIPLACE Pro Line Control GUI program
Start the program on the line computer SIPLACE Pro Line Control GUI
via the Windows Start menu
Start --> Programs --> SIPLACE Pro --> LCGUI
or
with the icon on your desktop.
Enter your user data.
The system connects to the SIPLACE Pro server and opens the user interface.
5.3.2 What to consider before switching on the stations
5
Check whether the stations are connected to the power and compressed air supplies.
Perform a sight check of the stations. Make sure that there are no obstacles in the travel
range of the gantries.
Make sure that the Z axes of all heads are in their uppermost end positions.
With waffle pack changer option: Switch the waffle pack changer on before you switch the ma-
chine on.
CAUTION
Before you switch on the stations, please perform the following steps.
5 Working with the machine User manual SIPLACE X-Series
5.3 Switching on the SIPLACE line From software version 710.0 Edition 12/2016
258
5.3.3 User classification
Certain functions or menus may only be executed or can only accessed by specially trained per-
sonnel. A differentiation is made between the following operator levels:
Production
Advanced production
Service (customer)
Service (SIPLACE)
The operator levels "Advanced production" and "Service (customer)" can be password protected.
The operator level "Service (SIPLACE)" is already password protected.
For a detailed description of the user classification, refer to section 5.1
, page 249.
5.3.4 Switching on the station and starting the station software user interface
5
Switch the station on at the main power switch.
After switching on, check whether the manometers show the required operating pressure.
The station computer software is loaded and the "Production" view of the station software is
shown for the "Production" operator level (see following diagram).
CAUTION
Communication problems when switching on the station!
Early switching on of station can lead to communication problems.
Only switch the station on if the monitor of the SIPLACE Pro computer shows the
"Desktop",