00198171-02_Technical_Training_FSE_TX-Series_EN.pdf - 第159页

10 JTF-ML 10.3 JTF (JEDEC Tray Feeder) - Operation Technical Training FSE SIPLACE TX-Series 01/2018 159 10.3.2 Button Description No. Item Description Remarks 1 Index 1 & 2 ● Index 1 and 2 (same time) trigger a tray …

100%1 / 168
10 JTF-ML
10.3 JTF (JEDEC Tray Feeder) - Operation
158 Technical Training FSE SIPLACE TX-Series 01/2018
Description Data
Maximum force on tray 2 N
Components size vs. Pocket size JEDEC Standard No. 95-1
For the full specification see the user manual delivered with your JTF.
Tray Specification extract
Tray width 135.9 mm + 0.25/ -0.13 mm
Tray length 322.6 + 0.25/ -0.13 mm
Thickness of thin trays 7.62 mm +/- 0.2 mm
Thickness of thick trays 12.19 mm +/- 0.2 mm
Max weight of tray 550 g
Max tray in the magazine 2.7 kg, 150 grams per tray for 18 trays
Warpage** Less than 0.8 mm over the entire surface
** Important is the flatness/ warpage 0.8 mm shall not exceed. Tray with larger warpage will lead to
jamming of the tray. Also important is the balance of heavy loaded trays. The center of gravity
needs to be in the center of the tray.
10.3 JTF (JEDEC Tray Feeder) - Operation
10.3.1 Overview
1. LED lamp green
2. LED lamp red
3. LED lamp yellow
4. LED lamp blue
5. Index 2
6. Elevator button
7. Inhibit button
8. Reset button
9. Stop button
10. Index 1
10 JTF-ML
10.3 JTF (JEDEC Tray Feeder) - Operation
Technical Training FSE SIPLACE TX-Series 01/2018 159
10.3.2 Button Description
No. Item Description Remarks
1 Index 1 & 2
Index 1 and 2 (same time) trigger a tray
exchange. The next tray in order will be
presented.
After the last tray the magazine drives
down and waits.
Open close the door to go on.
Not Active in produc-
tion mode.
2 Stop button
The stop button kills the air and motors
immediately.
A signal is sent to the host.
Active in production
mode.
3 Reset button
The reset button resets the feeder after
a Stop or Error condition.
A signal will be sent to the host.
Active in production
mode.
4 Inhibit button
Inhibits the feeder from receiving a tray
exchange command from the host,
push again and the Inhibit condition is
switched off.
Active in production
mode.
5 Elevator down
Enables to replace individual trays dur-
ing operation and without interrupting
production.
Not Active in produc-
tion mode
Continuous Run
Disconnect power cable of JTF, keep the button Inhibit(4) pressed and connect the power cable
for several seconds, the JTF will beginning with continuous run until press stop (2) or disconnect
the cable.
10.3.3 LED indication
No. Item/ Status Description
7 Green LED
- Ready
On Indicates a tray successfully reached the pick-position. A signal is
sent to the host. The LED goes off once the tray leaves the pick-
position.
Off Not ready to pick components, or, tray exchange is happening.
8 Orange LED
-Stop/ Error
On Stop-Condition, after pushing Stop.
Flash Error Condition. During the tray exchange a failure has happened.
The blinking pattern tells about what code. The signal is sent to
the host. Check RS232 Error Codes.
Off Normal operation.
9 Yellow LED
-Inhibit
On The Yellow LED indicated Inhibit, a signal is sent to the host. The
feeder does not accept tray exchanges.
Off Normal operation.
10 Blue LED
-Full/ Empty
On After a manual index of the last tray (highest slot number) in the
magazine the Blue LED goes on.
Off It indicated EMPTY, the elevator goes down. Open/close door to
reset condition.
10 JTF-ML
10.4 JTF (JEDEC Tray Feeder) - Power and Communication
160 Technical Training FSE SIPLACE TX-Series 01/2018
10.4 JTF (JEDEC Tray Feeder) - Power and Communication
1. Feed motor 5. Cylinder clamping Y
2. Power cable connector 6. Control board
3. Cylinder clamping X 7. Motor (lifting axis)
4. Tray pusher cylinder 8. Air distributor