TECHNICAL DATA SHEET
5
www.dct.cleaning
Power supply 400V, 32A, 50Hz (3+N+PE) UL 400V, 32A, 60Hz* (3+N+PE)
Pmax 12 kW 12 kW
Compressed air connection Pipe Ø 6 mm, Ø 10 mm Pipe ID 0.24 in, ID 0.39 in
Recommended working pressure 4,5- 6 Bar 65.25 – 87 PSI
Compressed air quality 3. Class ** 3. Class **
Exhaust pipe diameter Ø 100 mm ID 3.94 in
Exhaust pipe capacity 380 m3/h 13400 ft3/h
Minimum liquid for rst run 2 x 95 l 2 x 25.1 gal
Service space required around the device 600 mm 23.6 in
* When using frequency convertor
** According to the norm ISO 8573-1
INSTALLATION REQUIREMENTS
RIGHT
VIEW
Input air pressure Ø 6 mm, Ø 10 mm
ID 0.24 in, ID 0.39 in
input el. power
metric units imperial units
1170 mm
46.1 in
2015 mm
79.3 in
FRONT
VIEW
TOP
VIEW
1030 mm
40.6 in
227,81 mm
I
40.6 in
227,81 mm
I
40.6 in
Ø 100 mm
ID 3.94 in
Ø 100 mm
ID 3.94 in

InJet
®
3179 CRD
TECHNICAL DATA SHEET
6
www.dct.cleaning
1 process chamber – fully automatted solution
100% closed loop uid system
2 arm rotation – uid powered – cleaning
Cleaning and rinsing uid heating
Mechanical ltration
2 hot air blowers – drying
Chimney ap – electronically controlled
Pneumatic door lock
Emergency stop button
Manipulation wheels – lockable
PLC controller + 8,4“ touchscreen display
Spare parts (base kit)
STANDARD HARDWARE EQUIPMENT
Electronic monitoring of uid pressure
Electronic process cycle counter
3 levels of logging – operator, maintenance, engineer
Spraying uid pressure – continuous measurement
Standard software language mutation – CZ, ENG
Liquid and lter replacement notication – cycle counting
Possibility of 5 programs – setting option
Smart warning – low or high pressure level
Smart warning – low uid level
STANDARD SOFTWARE EQUIPMENT

InJet
®
3179 CRD
TECHNICAL DATA SHEET
7
www.dct.cleaning
SW for CVA calculation (android, machine)
Adjustable timer of heating – cleaning uid
Upgrade machine for PROTON
Language mutation (CZE, ENG, GER, POL, CHI, RUS, ITA, SPA, MAY, HUN)
ONLINE access to cleaning device
Other optional equipment - the complete list of optional accessories will provide you DCT or the local distributor.
OPTIONAL SOFTWARE EQUIPMENT
Common uids draining – manual control
Automatic uids relling (without pump)
Automatic uids discharging (without pump)
Tanker 200 and 400 l – cleaning / rinsing uid
Filtration 1PR sandwich – integrated
Filtration sandwich – external
Conductivity measurement of rinse uid 0–2000 µS – blocking optional
Other optional equipment - the complete list of optional accessories will provide you DCT or the local distributor.
OPTIONAL HARDWARE EQUIPMENT
Mechanical carrier frame – PCB
Mechanical carrier frame – frameless stencils
Mechanical carrier frame – squeegees
Traceability OFF line, CSV to SD card
Traceability OFF line, Reader, CSV to SD card
Traceability ON line, PC WIN, le
Traceability ON line, READER, PC WIN, le
Traceability ON line, PC WIN, OPC Server CD, no le
Traceability ON line, PC WIN, READER, OPC Server CD, no le
OPTIONAL ACCESSORY – FRAMES AND OTHERS
OPTIONAL TRACEABILITY