00198207-01_VB_BoardGateKeeper2.0_de_en.pdf - 第33页
Existing Restrictions SIPLACE BoardGateKeeper 2.0 33 6 6 E x is t in g R e s t r ic t io n s Existing Restrictions ▪ The Product Flow Controller is a CogiScan product. The ASM Ass embly System will not assume any liabili…
System Components and Features
SIPLACE BoardGateKeeper User Interface 5.1.2 BoardGateKeeper Manager
32 SIPLACE BoardGateKeeper 2.0
Existing Restrictions
SIPLACE BoardGateKeeper 2.0 33
6
6 Existing Restrictions
Existing Restrictions
▪ The Product Flow Controller is a CogiScan product. The ASM Assembly System will not assume any
liability for damage or accept warranty claims regarding the CogiScan Product Flow Controller.
▪ The restrictions described in the product documentation apply with regard to integration of the Co-
giScan Product Flow Controller.
▪ The Moxa box is a product made by Moxa. The ASM Assembly System will not assume any liability
for damage or accept warranty claims regarding the Moxa box.
▪ Moxa box and the integration of BoardGateKeeper Service do not support interlocking mode.
▪ The restrictions described in the product documentation apply with regard to integration of the Moxa
box.
▪ The OIB interface IBoardNotification supports the integration of several target systems with the
BoardGateKeeper per line (e.g. MES). The customer must ensure that these systems cooperate with
each other (for example with the same overrriding barcode).
▪ If you want to distribute IBoardNotification messages to different line-specific end points, you will
need to assign each end point to the SiplacePro line concerned, via the OIB Site configuration. For
further information, refer to the OIB product information ("Installation and Configuration of SIPLACE
OIB 4.x, item no.: 00197701-xx").
▪The Whispering Barcode option can only be enabled if there is a placement station with station soft-
ware 706 or higher at the beginning of the line.
▪ Some messages can only be processed with station software 709.1 or higher. With whispering, there
is, for example, the possibility to override the PCB barcode at the station or to transport the PCB to
the end of the SIPLACE cluster even if the barcode was rejected by the MES. It is generally recom-
mended to use software version 709.1 or higher for locking the PCB at the input conveyor of the
placement machine.
Existing Restrictions
34 SIPLACE BoardGateKeeper 2.0