Flux Dispenser (Optional) on SIPLACE 80F
4
Retrofitting Instructions
Edition 08/98
Page
12
from 14
Insert a full storage bin in the holder on the flux dispenser head.
Turn R26 and mark the position at which LED V21 turns on or off.
Turn R27 and mark the position at which LED V22 turns on or off.
NOTE
If you cannot turn a diode on, mark the right-hand stop on the potentiometer. However, if a light barrier cannot
be turned off, a fault exists.
As the final step, each of the 2 potentiometers, R26 and R27, is set in the middle between the 2 marks.
X4 X5 X3
X8
X7
Figure 4 “Component Illumination Board, Flux
V21
V22
R27
R26
Retrofitting Instructions Flux Dispenser (Optional) on SIPLACE 80F
4
Edition 08/98
13
from
14
3.7 Calibration
Activate the option flux applicator in the menu Miscellaneous/Machine Config. in SITEST
3.7.1 Distance of Pipette Tube <-> Component Camera Revolver Head
Slip the centering pin onto the pipette tube.
Press the sealing compound onto a PC board and move the board into the center conveyor.
Teach the flux dispenser head to a position over the sealing compound and press the centering pin down
into the sealing compound.
Record the this X- and Y-position.
Teach the PCB camera to the centered position over the impression in the sealing compound.
Ascertain the difference between the current X- or Y-position versus the recorded X- or Y-position.
Add the camera offset, factoring in the prefix of the result, and enter the value in the appropriate field in
SITEST.
3.7.2 Determining the Rinsing Position
By manually moving the portal by hand, move the pipette tube to the rinsing position.
Plug the axis test box onto the X/Y-star axis PC board.
Read the X- and Y-positions from the axis test box and record their readings.
Calculate the X- and Y-values of the rinsing position on the basis of the following example:
X- value = (Value of axis test box + Distance between pipette tube and compon. camera offset) x 2.5
= e.g., (214251 digit + 276 digit ) x 2.5
= 536318 µm
Y-value = (Value of axis test box - Distance between pipette tube to component camera offset) x 2.5
= (340255 digit - 103607 digit ) x 2.5
= 534938 µm
Enter the calculated values in Flux.ma.
DANGER O O O
Perform the following test of the rinsing position with just the “Key-operated switch ON” function, since there is
danger of a crash with the flux dispenser head if the rinsing position is entered incorrectly.
Flux Dispenser (Optional) on SIPLACE 80F
4
Retrofitting Instructions
Edition 08/98
Page
14
from 14