00198365-03_UM_JTF-ML2_TX12_V1-V2_EN.pdf - 第39页

4 Setting up and commissioning 4.2 Retrofitting in the SIPLACE TX-Series User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 39 Fig.56: Fitting the reject bin holder ► Fit the reject bin holder with …

100%1 / 94
4 Setting up and commissioning
4.2 Retrofitting in the SIPLACE TX-Series
38 User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019
Fig.54: Fitting the holder
► Fit the holder(2), using the two screws
ISO4762-M6x14-A2-70 [03043125‑xx]
provided, to the traverse bar(1).
When tightening the screws, press the
holder upwards, against the edge(3).
Fitting the reject bin holder with nozzle station for the SIPLACE TX Series V2
Fig.55: Fitting the reject bin holder
1. Nozzle station [03106821‑xx]
The nozzle station is fitted after meas-
uring the height.
2. Fastening screws of the nozzle station
[00333782‑xx]
3. Fastening screws for retaining bracket
ISO10642-M5x10-A2-70 [03082832‑xx]
4. Fastening screws of the complete
holder on the COT insert DIN7984-
M6x12-A2-70 [03081847‑xx]
5. Fastening screws ISO 7380-2 M 3 x 6-
A2-70 [03099571-xx], only for setting
the sensor height
6. Three lugs for cable ties
7. Sensor [03088550‑xx]
The sensor that is already installed and
cabled on the insert is used.
► Fit the individual parts of the reject bin holder.
► Use the cable ties to fix the sensor to the three lugs.
4 Setting up and commissioning
4.2 Retrofitting in the SIPLACE TX-Series
User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 39
Fig.56: Fitting the reject bin holder
► Fit the reject bin holder with two fasten-
ing screws DIN7984-M6x12-A2-70
[03081847-xx](1) on the COT insert.
Push the sensor cable behind the cover
as far as possible.
 CAUTION!
If too much cable length lies in front of
the cover, the reject bin may damage
the cable.
.
Fig.57: Fitting the NC holder
► Fit the right NC holder(1) with two
fastening screws DIN 7984-M6 x 12-
A2-70 [03081847-xx](2). The right NC
holder is replaced by the supplied ver-
sion without nozzle station.
Do not fit the NC and the nozzle station yet!
Fig.58: Setting the sensor
1. Reject box
2. Sensor
3. Distance 2.0+/-1.0mm
4. Fastening screws for setting the senor
height
► Insert the reject bin.
► Set the sensor to a distance of
2.0+/-1.0mm from the reject bin.
4 Setting up and commissioning
4.2 Retrofitting in the SIPLACE TX-Series
40 User Manual SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019
Fig.59: Fitting the holder
► Fit the holder(2), using the two screws
ISO4762-M6x14-A2-70 [03043125‑xx]
provided, to the traverse bar(1).
When tightening the screws, press the
holder upwards, against the edge(3).
Fitting the empty tape duct and removing the nozzle changer
Fig.60: Fitting the empty tape duct and cover
► Fit the short empty tape duct(1), using
two ISO4762-M6x14-A2-70
[03043125‑xx] screws.
► Fit the "hand guard tape cutter"(2)
[03130649‑xx] with two screws
ISO4762-M6x14-A2-70 [03043125‑xx].
Fig.61: Removing the NC holder
Perform the following steps on the dis-
mantled NC holder:
► Remove the screw(2) fastening the
support(1) and remove this.
► Remove the screw(3) fastening the
nozzle station and the reject bin
holder(4) and remove this.
 NOTICE!
The previously used nozzle station is
no longer needed.
.
► Close open pneumatic connections if
necessary.