Trac eability with PCB C amera / Ins tal lation Ma nual Ausg abe 05/2 014 E dit ion 8 1.8 Restr ictions The f ollowing restr ictions appl y to th e PCB Barcode f unction V3.0: – The f unction is o nly suppor ted as of SI…
Traceability with PCB Camera / Installation Manual Ausgabe 05/2014 Edition
7
1.6 Enabling the PCB Barcode Function
The PCB Barcode function has to be enabled in SIPLACE Pro.
► In the Station Editor, enable the PCB barcode reader option for the first station in the line and
the Whisper Down the Line option for each station in the line.
► In the Setup Editor, select the Inkspots and Panel Fiducials and PCB Barcodes edit fields
and then select the appropriate mode for Whisper Down the Line.
The barcode fiducials can be edited and enabled/disabled for the barcode recognition under the
Barcode Fiducial tab in the Board Editor.
Detailed information about the PCB Barcode function settings can be found in the online help to
SIPLACE Pro and in the SIPLACE Traceability User Guide, item no. [00197472-xx].
1.7 Testing the PCB Barcode Function
You can test the PCB Barcode function with SIPLACE Pro and the station software.
In SIPLACE Pro:
► Create a new board in the Board Editor.
► Create a new fiducial of the type PCB Barcode in the Fiducial Editor and enter dimensions
and tolerances.
► Create at least one component for the board in the Component Editor.
► Assign the component and the barcode fiducial to the board in the Board Editor.
► Define the placement program for the station.
More information about the single steps can be found in the "Getting Started with SIPLACE Pro"
manual and in the online help to SIPLACE Pro.
In the station software:
After the placement program has been downloaded to the station:
► Teach the PCB barcode under Teaching fiducials in the Board view.
More information about this can be found in the online helps to the station software and SIPLACE
Vision.
Traceability with PCB Camera / Installation Manual Ausgabe 05/2014 Edition
8
1.8 Restrictions
The following restrictions apply to the PCB Barcode function V3.0:
– The function is only supported as of SIPLACE Pro version 11.2 and station software version
707.1 (and in compatible mode 706.2).
– Station software V60x is not supported.
Traceability with PCB Camera / Installation Manual Ausgabe 05/2014 Edition
9