SM_SXDX12_intern_03-2017_en.pdf - 第14页
Introduction Abbreviations SIPLACE on the World Wide Web (WWW) 14 Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2 1.5 Abbreviations Abbreviations Description PA, PA1, PA2 Placement area, Plac ement area 1, Placement ar…
Introduction
Validity of Document Staff Qualifications and Training
Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2 13
1.3.5 Validity of Document
This document contains service work instructions for all SIPLACE SX1/SX2/DX1/DX2 machines.
The service work described in this manual is divided into modules and is largely identical for all machine
types:
▪ If the work required for specific machines should differ from the standard procedure, this will be in-
dicated with reference to the machine number, series and delivery state.
▪ Diagrams should be seen as examples e.g. the diagram of a SIPLACE SX1 or machine with different
paint finish does not mean that the following information only applies to the machine type shown.
The main focus of this manual is on a description of mechanical service work.
Please refer to the circuit diagram folder for any electrical checks:
▪ SIPLACE SX1/SX2/DX1/DX2 detailed circuit diagrams [00196475-xx] (German/English)
1.3.6 SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE
®
homepage at http://www.siplace.com.
► You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can access the
SIPLACE User Group
. Here you can call up special
information about our placement systems e.g.
▪ Technical documentation,
▪ Technical information,
▪ Spare parts lists etc.
Registration for the user group is very simple:
► Click on the Register link.
► Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with USER ID and password.
1.4 Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op-
eration and maintenance of placement machines and add-on devices and are suitably qualified. e.g:
▪ Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
▪ Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord-
ance with normal safety standards.
▪ Have received first aid training.

Introduction
Abbreviations SIPLACE on the World Wide Web (WWW)
14 Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2
1.5 Abbreviations
Abbreviations Description
PA, PA1, PA2 Placement area, Placement area 1, Placement area 2
CO Component
COT Changeover table
COT-i Changeover table insert
C&P Collect&Place
C&P12, CP12 Collect&Place head with 12 segments
C&P20, CP20 Collect&Place head with 20 segments
C&P6, CP6 Collect&Place head with 6 segments
CPP Collect&Pick&Place head
CPx Collective term for CPP, CP20, CP12 and/or CP6
DC Dual conveyor with 2 lanes
ESD Electrostatic sensitive device
EMC Electromagnetic compatibility
SC Single conveyor with 1 lane
FHE Fast Head Exchange
PCB Board
P&P Pick&Place
QC Quad lane conveyor with 4 lanes
SCS Single Core Solution
SC Station computer
TH TwinHead
VS Vision system type
WPC Wafflepack Changer
WPC4/5/6 Waffle Pack Changer Version 4/5/6
ID Intermediate distributor
ID1, ID2 Intermediate distributor 1, intermediate distributor 2

Service Work
Overview
Service Manual (Internal) SIPLACE SX1/SX2/DX1/DX2 15
2 Service Work
2.1 Overview
Preparing the gantry lift
Remove the gantry carrier from the transportation case with the gantry lift and lock into place.
See also the "Assembly Instructions Gantry Modularity" [00196626-xx]. SX1/SX2
Preparing the Machine
Remove the changeover table
Switch off the machine.
Remove the keyboard and open the two side covers.
Push the gantry into a suitable working position in the machine.
NOTICE
Chapter
3.3.1 The Gantry lift
Locking and Transporting the Gantry Carrier
Transportation Locks and Tilt Guard