3.22 1.000 TT5453
TT5453TT5453
TT5453 1
11
1 CriticalBug
CriticalBugCriticalBug
CriticalBug AllMachine
Application
exit
Therewasabugthatmightcausethemachineapplicationabnormalendwhenvarious
errorsoccurredoneafteranother.
Itisfixed.
3.22 1.000 TT5372
TT5372TT5372
TT5372 2
22
2 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL Editor
Whenthefollowingprocedureswereexecuted,therewasabugthatacombinedboard
datacannotbesaved.
1.ThemounterapplicationwhoseversionisV3.21STDR1.000orlaterisused.
2.Click[Editor].
3.Selectacombinedboarddataon[File]-[OpenBoardData].
4.Although[File]-[SaveBoardData]isselected,thecombinedboarddatacannotbe
saved.
Itisfixed.
3.22 1.000 TT5374
TT5374TT5374
TT5374 3
33
3 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL Editor
Whenthefollowingprocedureswereexecuted,therewasabugthatacombinedboard
datawassavedwithouttheoverwriteconfirmation.
1.ThemounterapplicationwhoseversionisV3.21STDR1.000orlaterisused.
2.Click[Editor].
3.Loadacombinedboarddatafrom[File]-[OpenBoardDatainthisEditor].
4.On[Boarddatasave]window,select[SaveBoardDataAs...],theninputthe
combinedboardnamewhichalreadyexists.
5.Click[Save]button.
Itisfixedsothat
[Ea12046:FILE
OVERWRITE]will
bedisplayed.
3.22 1.000 TT5400
TT5400TT5400
TT5400 4
44
4 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL Optimization
Whenallofthefollowingconditionsweresatisfied,therewasabugthatoptimization
succeededbymistakealthoughitshouldfailand[Ea131:BOARDDATAERROR]should
occur.Thisbugmightcausemismountingbyusingtheboarddata.
1.YS24(X)DLexistsintheline.
2.Boarddataformatis"YGX(Combined)".
3.Thereisapartsdatawhichisin[Board]-[Mount]-[P.No.]butisnotused.
Itisfixed.
3.22 1.000 TT5387
TT5387TT5387
TT5387 5
55
5 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL CycleStop
Whenthefollowingprocedureswereexecuted,therewasabugthataboardcarriedout
withoutcompletingthemounting.
1.Conditions
1)[Board]-[MountMode]is"EachLanes".
2)[Setup]-[CycleStop]is"ON".
2.Procedures
1)Whenboardsexistinbothconveyorlanes,tap[CycleStop]button.
2)Press[RESET]button.
3)Restartauto-running.
Itisfixed.
3.22 1.000
TT5267
TT5267TT5267
TT5267
TT5376
TT5376TT5376
TT5376
TT5433
TT5433TT5433
TT5433
6
66
6 CriticalBug
CriticalBugCriticalBug
CriticalBug Printer Auto-running
Whenthefollowingprocedureswereexecuted,theprintermightoccasionallybecome
sleep.
1.Press[EMERGENCYSTOP]buttonduringauto-running.
2.Press[RUN]buttonontheoperationpanel.
Itisfixed.
3.22 1.000 TT5104
TT5104TT5104
TT5104 7
77
7 CriticalBug
CriticalBugCriticalBug
CriticalBug Printer Auto-running
Whenthefollowinginterlockerrorsoccurred,forexample,theprinterapplicationmight
becomesleep.
1.[Ea8050:FLAPUPINTERLOCK]
2.[Ea8055:CLEANERFREEINTERLOCK]
3.[Ea8059:UNABLETOMOVEAXISWITHABOARDONTHECONVEYOR]
Theotherinterlockerrorsarethesame.
Itisfixed.
3.22 1.000 TM2284
TM2284TM2284
TM2284 8
88
8 Add Mounter Feeder
ThefollowingFeedertypeshavebeensupported.
1.88mmTape
2.104mmTape
3.120mmTape
4.136mmTape
5.152mmTape
6.168mmTape
7.184mmTape
8.200mmTape
Itismodified.
3.22 1.000 TM2413
TM2413TM2413
TM2413 9
99
9 Add Printer Boarddata
When[Print]-[Basics]-[MaskSize]is"750[mm]*650[mm]"inaboarddata,the
maximumvalueof[BoardSizeY(mm)]hasbeenchangedasfollows.
Beforethechange:250mm
Afterthechange:330mm
Itismodified.
3.22 1.000 TP1901
TP1901TP1901
TP1901 10
1010
10 Add Optimizer Fixedboard
Ithasbeenmodifiedsothattheoptimizercancreatetheresultthatisbetterfor
parallellanesmountingwhenitisexecutedwithparallellanesmountingandwiththe
settingwhichusefixedboardin[Setoptimizationparameter]–[Detail].
Itismodified.
3.22 1.000 TT5296
TT5296TT5296
TT5296 11
1111
11 Change AllMachine GUI
When"FileFormat"or"Lanenumber"on[Setup]-[BoardExplorer]ischanged,ithas
beenchangedsothatthefileformatandthelanenumberonthefollowingscreenwon't
changedependingonit.
1.[Setup]-[Board]
2.[Save]
Therefore,itisabletoselectorsaveanintendedboarddata.
Itismodified.
MDOC-VG30-00001 7/11

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2010/7/13
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.22 1.000 TP1740
TP1740TP1740
TP1740 12
1212
12 Change Mounter GUI
Theusageof[ServerPath:]on[Setup]-[SoftwareSetting]-[Network]-[Network
setting]hasbeenchangedasbelow.
Before:boarddata,POSinformation,RetryinformationandHistory
After:boarddatalocation
Therefore,the[Network]buttonsonthefollowingscreensweredeleted.
WhenyouchoseafolderintheNetwork,selectitfrom[Folder]button.
1.[Parts]-[PartsAdj]-[RandomBall]-[ReadPOS]
2.[MIS]-[SaveLog]
3.[Unitlog]-[SaveLog]
4.[Monitor]-[Retry]-[Save]
Itismodified.
3.22 1.000 TP1882
TP1882TP1882
TP1882 13
1313
13 Change YS24(X)DL GUI
Thefunctionthatmakesitpossibletodeterminethataboarddataonthescreenisfor
whichlanehasbeenaddedtostatusareawhenproductionisperformedinonlyone
lane.
Before:OnlyAAAwasdisplayed.(Thiscan'tdeterminewhichlaneitis.)
After:Thecaseproductionisperformedinlane1.
(1)AAA
(2)
Thecaseproductionisperformedinlane2.
(1)
(2)AAA
Thecaseproductionofthesamesideofboardisperformdinbothlanes.
(1)AAA
(2)AAA
Itismodified.
3.22 1.000 TT5189
TT5189TT5189
TT5189 14
1414
14 Bug Mounter
Schedule
Specification
Whenthefollowingprocedureswereexecuted,therewasabugthatcausedtheshaft
blowwithanozzlewhichitwasnotabletobeperformedwith.
1.Conditions
1)On[Setting]–[SpecificationInformation]–[ScheduleSpecification]-[Shaft
CleaningBlow],
(1)[CycleCondition]issettothevalueexcluding"0MinutesInterval".
(2)[NozzleType]issetto"OnlyUsingNozzle".
2)Therewasbothnozzleswhose[Setting]–[SpecificationInformation]–[Mount
NozzleSpecification]-[NozzleData]-[NozzleType]-[Cleaning-Blow]is"Use"and
"NotUse".
2.Procedures
1)Turnoffthemachineafterchanginganozzletotheonewhose[Cleaning-Blow]is
"NotUse".
2)Thetimerunsbeyondthevaluesetinschedulespecs.
3)Theshaftblowoftheschedulespecsisexecutedafterperformingreturn-to-origin.
Itisfixed.
3.22 1.000 VCI0008
VCI0008VCI0008
VCI0008 15
1515
15 Bug Mounter Vision
Whenallofthefollowingconditionsweresatisfied,therewasabugthatrecognition
succeededalthough[Ea00005:LEADNUMBERERROR]shouldhaveoccurredatthat
time.
1.Apartsusestheco-planaritychecker.
2.[Parts]-[Shape]-[AlignmentType]is"SOP","QFP"or"OffLead".
3.Moreleadsarerecognizedonthepartsthanthevalueof[Parts]-[Shape]-[Lead
Number].
4.Leadwidthofthepartswhichisrecognizedisassameasthevalueof[Parts]-
[Shape]-[LeadWidth]orwithinthetolerancewhichisseton[Parts]-[Vision]-
[Comp.Tolerance].
5.Leadpitchofthepartswhichisrecognizedisassameasthevalueof[Parts]-
[Shape]-[LeadPitch]orwithinthetolerancewhichisseton[Parts]-[Vision]-
[Comp.Tolerance].
Itisfixed.
3.22 1.000 TP1929
TP1929TP1929
TP1929 16
1616
16 Bug Mounter Monitor
Whenthefollowingprocedureswereexecutedintheremotecontrol,therewasabug
thatthevalueotherthan"0"isinputto[Monitor]-[Detail]-[Rest:]textboxby
mistake.
1.Select[Menu]-[Production]-[Productionconditionsetup].
2.Inputthevaluewhichisbiggerthanthatof[Prod.BoardCountMax.]textboxto
[Prod.BoardCounter]textbox.
3.Click[OK]button.
Itisfixedsothat
"0"wilbeinput.
3.22 1.000 TT5295
TT5295TT5295
TT5295 17
1717
17 Bug Mounter Boarddata
WhenanyofthefollowingprocedureswereexecutedintheLineRemoteControlfora
VIOSdata,therewasabugthatthemounterapplicationabnormalendoccurred.
1.[Production]-[Boarddatacommunication]-[Send]buttonisclicked.
2.[Production]-[Boarddatacommunication]-[Receive]buttonisclicked.
Itisfixed.
3.22 1.000 TT5341
TT5341TT5341
TT5341 18
1818
18 Bug YS24(X)DL
Conveyor
width
Whenthefollowingprocedureswereexecuted,therewasabugthatbegantocarrya
boardinwithoutarrangingtheconveyorwidthandpossiblycausedittofall.
1.Aboarddatawhichistomountinonlyonelaneisloaded.
2.Press[RUN]button.
3.Tap[OK]buttonon[Ea12190:Conveyorwidthisnotreadyforproduction]dialogbox.
4.Tap[Cancel]buttonwhiletheconveyerwidthisbeingchanged.
(Startauto-running,andaboardiscarriedin.)
Itisfixed.