TM1789.History output of specified time.pdf - 第3页
SMT Software En gineering Group IMOperations YAMAHAMOTORCO.,LTD. MD OC-SOFT50042 3/6 3. Setting s 3.1. Settings of the “history output of specified time” f unct ion Click [SetUp] - [S oftware Set…

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50042
2/6
1. Introduction
The target model and the target version of this specification are as follows.
Table 1.1 Target model and object version of this function
Item name Object Remarks
Target model YS Series Mounter,YG12 Series Mounter, YG300,YSP
Object version V3.26STD R1.000 or later
2. Summary
This function is to set a time to output history files of [MIS] and [Unit log].
Please use this function if you need history files according to your working hours.
(Previously, it was outputted on the fixed time, 0:00 o'clock)
In addition, it is able to reset the history (history delete) when [Unit Log] files are outputted.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50042
3/6
3. Settings
3.1. Settings of the “history output of specified time” function
Click [SetUp] - [Software Setting] - [History] - [Detail History Setting].
• [The history is output at specified time] Check Box
Check the box if you specify outputting time of history files.
The default setting is “unchecked state”, in this case, the history file is outputted at 0:00.
When the check box is “checked state”, 0:00 o'clock output is not executed.
• [Specified time] Text Box
Set a time (from 0:00 to 23:59) to output history files.
• [After the history output, the unit logs are reset] Check Box
It is the same operation as the tapping [Unit Log] – [(each history)] – [Operator] - [Reset] button
after the history file is outputted.
Check the box if you want to reset [Unit Log] after outputting the history.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT50042
4/6
4. Details
4.1. Output target of the history file
The output target of the history files are as follows.
Mounter
[MIS]-----Error log, Board log, Program log, Setup log
[Unit Log]----- Head, Nozzle, Feeder, Conveyor, Parts, Feeder ID
Printer
[MIS]-----Error log, Board log, Program log, Setup log
[Unit Log]----- Conveyor, Squeegee,Mask,Cleaner
(The [MIS by Board] history is not included in this function.)
4.2. Reset operation
[Unit Log] is reset after the history is saved.
It is possible to reset it by tapping the [reset] button under the history screen as well.
After the operation is completed, [Ea12779: The auto reset of History data was executed.] is
recorded in [MIS] - [Log].
4.2.1. Reset target of the History
The following screens of [Unit Log] are reset.
Mounter
"Operator" information on Head, Nozzle, Feeder, Conveyor and Feeder ID.
"Current data" information on parts history.
Printer
"Operator" information on , Conveyor, Squeegee,Mask, and Cleaner.
"Current data" information on parts history.
4.2.2. Notice of reset operation
When the machine is turned off in the specified time, the reset is done when the machine started
next.
(The data until the day before is saved at the machine turn-off.)