TDS_AirJet_954_CRD_ENG.pdf - 第5页
AirJet ® 954 CRD TECHNICAL DATA SHEET 5 www.dct.cleaning Power supply 400V, 32A, 50Hz (3+N+PE) UL 400V, 32A, 60Hz* (3+N+PE) Pmax 9,5 kW 9.5 kW Compressed air connection Pipe Ø 6 mm Pipe ID 0.24 in Recommended working pre…

AirJet
®
954 CRD
TECHNICAL DATA SHEET
4
www.dct.cleaning
Dimensions (w x l x h) 2350x 1140 x 2150 mm 92.5 x 44.9 x 84.6 in
Weight 630 kg 1388 lbs
Ø energy consumption per cycle 1,65 kWh 1.65 kWh
Cleaning and rinsing uid consumption
per cycle
0,05 – 0,3 l 0.01 gal – 0.08 gal
Compressed air consumption per cycle 83 l / 5 Bar 21,93 gal / 72.5 PSI
Max. dimensions of the cleaned parts 870 x 440 x 320 mm 34,2 x 17,3 x 12,6 in
Exchangeable mechanical lter of cleaning
and rinsing uid
5 – 200 μm 5 – 200 μm
Cleaning uid ow rate 200 l / min 52.8 gal / min
Temperature range setting of the cleaning
and rinsing uid
From ambient temperature to 60°C From ambient temperature to 140°F
Conductivity range settings of the rinsing
uid in the tanks.
0 – 2000 μS/cm * optional 0 – 2000 μS/cm * optional
Temperature range setting of the drying From ambient temperature to 80°C From ambient temperature to 176°F
Noise level < 70 dB < 70 dB
Device control PLC + 8,4“ touchscreen PLC + 8.4“ touchscreen
Volume of the storage tanks 225 l 59,44 gal
TECHNICAL PARAMETERS
DIMENSIONS
MINIMUM SERVICE SPACE
AROUND THE MACHINE
600 mm
23.6 in
600 mm
23.6 in
600 mm
23.6 in
600 mm
23.6 in
2350 mm
92.5 in
1710 mm
67.3 in
1140 mm
44.9 in
2150 mm
84.6 in
metric units imperial units

AirJet
®
954 CRD
TECHNICAL DATA SHEET
5
www.dct.cleaning
Power supply 400V, 32A, 50Hz (3+N+PE) UL 400V, 32A, 60Hz* (3+N+PE)
Pmax 9,5 kW 9.5 kW
Compressed air connection Pipe Ø 6 mm Pipe ID 0.24 in
Recommended working pressure 4,5 – 6 Bar 65.25 – 87 PSI
Compressed air quality 3. Class ** 3. Class **
Exhaust pipe diameter Ø 100 mm ID 3.94 in
Exhaust pipe capacity 380 m
3
/h 13 400 ft
3
/hod
Minimum liquid for rst run 2 x 200 l 2 x 52.8 gal
Service space required around the device 600 mm 23.6 in
* When using frequency convertor
** According to the norm ISO 8573-1
INSTALLATION REQUIREMENTS
BACK
VIEW
BACK
VIEW
715 mm
28.1 in
discharge of the fluids G1
input el. power
input air pressure Ø 6 mm
input air pressure ID 0.24 in
2150 mm
84.6 in
2350 mm
92.5 in
735 mm
28.9 in
Ø 100 mm
ID 3.94 in
115 mm
4.53 in
metric units imperial units

AirJet
®
954 CRD
TECHNICAL DATA SHEET
6
www.dct.cleaning
1 process chamber – fully automatted solution
100% closed loop uid system
Cleaning and rinsing uid heating
Pneumatic door lock
Mechanical ltration
3 hot air blowers – drying
Emergency stop button
Manipulation wheels – lockable
PLC controller + 8,4“ touchscreen display
Spare parts (base kit)
STANDARD HARDWARE EQUIPMENT
3 levels of logging – operator, maintenance, technician
Standard software language mutation – CZ, ENG
Liquid and lter replacement notication – cycle counting
Possibility of 5 programs – setting option
STANDARD SOFTWARE EQUIPMENT