manual-flexible-arm-fume-extractor-jbc-0035523_ID-255368_EN.pdf - 第5页

40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm par a manuales - neg r o plano 200 mm 300 mm 70 cm / 27.6 in max. w w w .jbc t ools .c om ST A TION 1 F ilt er ST A TION 2 POR T 1 PED AL 1 PED AL 2 F AE2 FUME EX TR A C T OR …

100%1 / 8
100 cm / 39.4 in max.
4
Hanging arm
no distance
To avoid breaking the arm, do not extend the
arm more than 100 cm / 39.37 in from the
center of its base and do not go below the
minimum bend radius of 20 cm / 7.87 in.
workbench
breakage
Do not install the flexible arm on shelves or
higher levels than the work bench. Forced
bending radii can cause the arm to break.
How to use
min. bending
radius
20cm
7.87in
Max. operating distance
1.00m / 39.37in
Arm Installation
Arm Positioning
Thanks to the flexibility of
the arm, its position can be
adapted to the particular
working environment and
conditions.
... or with the nozzle resting on
the workbench.
The arm can be used in an
upright position with the nozzle
hanging over the workplace ...
Nozzle resting
on the workbench
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - negro plano
200 mm
300 mm
70 cm / 27.6 in max.
www.jbctools.com
STATION 1
Filter
STATION 2
PORT 1
PEDAL 1 PEDAL 2
FAE2
FUME EXTRACTOR
PORT 2
STATION 3 STATION 4
OK
70 cm / 27.6 in max.
www.jbctools.com
STATION 1
Filter
STATION 2
PORT 1
PEDAL 1 PEDAL 2
FAE2
FUME EXTRACTOR
PORT 2
STATION 3 STATION 4
OK
5
To plug the windings back in,
align them with each other and
firmly push them together.
If the flexible arm loses
firmness, it must be re-
compressed.
To increase compression, turn
the arm slightly clockwise.
Once the arm is compressed,
readjust its position.
To install a new nozzle, turn
the nozzle bayonet clockwise
to lock it in place.
Nozzle Replacement
Windings Compression
Note: In case of breakage, the
windings can be plugged back
into each other.
Nozzle and tube are connected
to each other by means of a
bayonet lock. This makes it
easy to replace the nozzles.
Disassemble the nozzle by
holding the tube with one
hand. With the other hand turn
the nozzle counter-clockwise
and pull it out.
70 cm / 27.6 in max.
6
Clamp Dimensions
~57mm
~2.24in
~5mm
~0.20in
~72mm
~2.83in
~84mm
~3.31in
max. opening ~60mm
~2.36in