00197483-02_VD_SIPLACE-OIB-3.3_EN.pdf - 第22页

Version Descripti on SIPLAC E OI B 3.3 04/2014 E dition 22 7 Functio ns in SIP LA CE OIB Monit oring Serv ice Adap ter The f unctions of the SIPLA CE OIB Mo nitorin g Adapter are → Online Stat ion Eve nts → Board sum m a…

100%1 / 32
Version Description
SIPLACE OIB 3.3 04/2014 Edition
21
6.4 Checking for Setup Center Availability
General
The SIPLACE OIB Setup Center Adapter is a service that will be started when the computer starts and
Setup Center is a GUI application which can be closed. When SIPLACE Setup Center is closed no
material control events are forwarded to SIPLACE OIB. If the information flow is critical the adapter can
check the communication to Setup Center and trigger an escalation email for the disconnected
communication.
Configuration
By default the installation is configured NOT to check for maintained connection.
It can be adjusted in the oib section under configuration->oib in the config files in the installation directory.
<siplaceSetupCenter factoryLocation="TEST.TEST.TEST"
setupCenterSCIPortOut="8001" setupCenterSCITimeOut="60000"
setupCenterPerformProductionEvents="true"
setupCenterPerformUnknownEvents="true"
setupCenterUseProductionEventCache="true"
setupCenterUseProductionEventCacheTimeSpan="60"
setupCenterMSMQMessageThreshold="500"
setupCenterMSMQWatchdogActivation="true"
setupCenterMSMQWatchDogCheckTimeSpan="3600000"
setupCenterDisconnectedWatchdogActivation="false"
setupCenterDisconnectedWatchDogCheckTimeSpan="300000">
Changing the value from setupCenterDisconnectedWatchdogActivation to true will enable the check
functions. Changing the value setupCenterDisconnectedWatchDogCheckTimeSpan will change the time in
milliseconds, after which time of being disconnected an escalation email will triggered.
Version Description
SIPLACE OIB 3.3 04/2014 Edition
22
7 Functions in SIPLACE OIB Monitoring Service Adapter
The functions of the SIPLACE OIB Monitoring Adapter are
Online Station Events
Board summary with
o Used material
o Identification and Vacuum errors
o Related SIPLACE Pro and Setup data
o Component names
A combined data model including the separated SIPLACE OIS/SIS data in a common structure.
8 Functions in SIPLACE OIB Client API
8.1 Installing Assemblies into the GAC together with a policy file
This behavior of the SIPLACE OIB Client API will enable to update the SIPLACE OIB Smart Proxy
assemblies at the customer site. This might be required for bug fixes in the Smart proxies.
The policy files will redirect the existing application to use the new versions of the Smart Proxy assemblies
in the GAC. The SIPLACE OIB Client API installation will take care that the upgrade of these components
will be performed automatically.
Please see also the chapter “2.7 Upgrading with SIPLACE OIB” in the 00197480-02_IM_SIPLACE-OIB-
3.3_EN.pdf document.
Version Description
SIPLACE OIB 3.3 04/2014 Edition
23
9 Restrictions
9.1 General Restrictions
Due to the dependency of the API to the underlying SIPLACE products, the content and the functionality of
the exposed API depends on the configuration of the overall system. Please see the adapter version
description of the target adapter for details.
9.2 Restrictions for the Line Control Adapter
The SIPLACE OIB Line Control Adapter must be installed on the same computer as the Line Control
Server has been installed.
9.3 Restrictions for all SIPLACE Pro Adapter Versions
All SIPLACE OIB SIPLACE Pro Adapters require an SPI installation of the target version of SIPLACE Pro
on the same machine.
The installation can be implicitly by installing a SIPLACE Pro product like SIPLACE Pro Desk
on this computer or you can explicitly install the interface by starting the SIPLACE Pro Installer and select “SIPLACE
Pro Interface” as the installation type.
9.4 SIPLACE OIB Setup Center Adapter
When operating the SIPLACE OIB Setup Center Adapter together with the XML Import Service it might
happen that the system is not operating properly, when the event log configuration from Windows is not
setup appropriately.
Workaround: Ensure that the Application event log is setup for “Overwrite events when required”
9.5 Setup Center in General
This chapter describes restrictions concerning the whole Setup Center application.
- For all used components, “verification” has to be activated in SIPLACE Pro.
- The setting “Setup Verification System” of a used setup has to be set to “External … System” in
SIPLACE Pro.
- There has to be configured a line in Setup Center.
- Setup Center only works in unique ID mode, ICL mode is not supported by SIPLACE OIB. Therefore the
barcode definitions have to define a barcode with barcode fragment “UniqueId”.
- Table management is supported with restrictions. Table announcement is only possible at the station on
site. Therefore a table has to be announced first manually, before machine control operations may be
executed via Setup Center Interface. Events have no restrictions.
- Quantity printout for ICL mode has to be disabled.
- XML import has to be disabled.