222085 Issue 1 - Horizon APiX Appendix Manual.pdf - 第46页
TECHNICAL REFERENCE APPENDIX M37 POWER SUPPLY ENCLOSURE Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.9 W ARN ING LETHAL VOL T AGE. DANGEROUS VOL T AGES EXIST IN THIS EQUIPMENT . ENSURE ALL ELECTRONIC CO…

TECHNICAL REFERENCE APPENDIX
M37 POWER SUPPLY ENCLOSURE
3.8 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
M37 POWER SUPPLY ENCLOSURE
Item Description Item Description
1 M37 Power Supply Enclosure 3 Two Button Control
2 Front Cover Interlock 4 System Button
View on Arrow A
4
2
3
1
A

TECHNICAL REFERENCE APPENDIX
M37 POWER SUPPLY ENCLOSURE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.9
WARNING
LETHAL VOLTAGE. DANGEROUS VOLTAGES EXIST IN THIS EQUIPMENT.
ENSURE ALL ELECTRONIC COVERS AND MAIN MACHINE COVERS ARE
FITTED BEFORE OPERATING THIS EQUIPMENT.
Mains input power (115V to 230V) to the machine is routed via the mains isolator
switch and the M39 EMO enclosure. From the M39 enclosure it is fed to the M37
power supply crate, through the cable gland at the rear panel, to the three
terminal blocks TB1 (live), TB2 (neutral) and TB3 (earth). From the terminal
blocks mains power is supplied to the following:
• M37SK31 PC Supply
• M37SK32 Monitor Supply
• M37SK33 Spare
• M37SK34 Spare
• M37SK35 Internal Vac Pump via Mains Filter and CB34
• PSU
PSU is a Switched Mode Power Supply Unit (SMPSU) which converts the ac
into the following dc supplies:
•+24V US
• +24V SW
•+5.5V
•+12V
•-12V
•+42V
The dc supplies from the PSU is fed to the power distribution PCB. Mounted
on the power distribution PCB is the PSU monitor board which enables moni-
toring of the power supplies.
A printhead cover loop consisting front cover interlock, interlock blanking plug
and E Stop relay are fitted to ensure motor power is removed if the front
printhead cover is opened.
A two handed safety relay, left jog button and right jog button are fitted to enable
certain functions to be performed with the front printhead cover open.
NOTE
Following a service visit that involves any disturbance of components in the
mains voltage circuit an electrical test as detailed in the Pre Power section of
the Transportation chapter must be undertaken. Before testing ensure that the
machine is isolated from the factory supply and that any external equipment (ie
upline and downline conveyors) are disconnected.

TECHNICAL REFERENCE APPENDIX
ELECTRICAL SCHEMATIC
3.10 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
ELECTRICAL SCHEMATIC
M37 Power Supply Crate
CB 32
10A
PSU 1
+24V
-12V
+12V
+5.5V
+42V
Internal Vac Pump
CB34
16A
Filter
TB2
TB3
L
N
E
Mains Isolator
TB1
M37SK31
PC Supply
M37SK32
Monitor Supply
M37SK33
Spare
M37SK34
Spare
M37SK35
Internal Vac Supply
CB33
10A
2 Handed
Safety Relay
PIHZ X1
RL2
E Stop Relay
PNOZ X2
RL1
M37TB01
Power Distribution PCB
M37SK36
Part
CON1
Part
CON2
Part
CON3
CON 1
CON 3
CON 2
Fan
PSU Monitor Board
M37PL28
M37PL29
MMI
M37SK27
Safety I/O
M37PL26
M37SK24
E Stop Blanking Plug
M37SK30
USB Port
M37SK23
Rear Cover Interlock -
Interlock Blanking Plug
M37SK22
Front Cover Interlock
M37SK21
Spare Servo Motor Power
M37SK20
RTC I/O Node 11
M37SK19
Camera Y I/O Node 9
Servo Motor Power
M37SK18
Camera X I/O Node 8
Servo Motor Power
SpareM37SK01
Rising Table I/O Node 6
Servo Motor Power
M37SK16
M37SK17
Print Carriage I/O Node 7
Servo Motor Power
Low Current DCM37SK02
High Current DC
M37SK03
Machine I/O Node 2
M37SK04
Print Carriage I/O Node 3
M37SK05
USC I/O Node 4
M37SK06
Not Used
M37SK07
Paste Dispense I/O Node 10
M37SK08
HTC M27 - RTC I/O Node 12 -
Dual Lane I/O Node 15
M37SK09
Grid-LokM37SK10
Internal Lighting & Ionizer
M37SK11
+12V Spare
M37SK12
Remote Barcode Reader
M37SK13
Hand Held Barcode Reader
M37SK14
Machine Fans
M37SK15
M37SK25
E Stop Buttons