222085 Issue 1 - Horizon APiX Appendix Manual.pdf - 第63页

TECHNICAL REFERENCE APPENDIX PNEUMATIC MODULE 3.26 Appendix to Micron Technical Manuals Chapter Issue 1 June 15 PNEUMA TIC MODULE Item Description Item Desc ription 1 Machine Front Soleno ids 4 External Connection 2 Filt…

100%1 / 166
TECHNICAL REFERENCE APPENDIX
UNDERSCREEN CLEANER
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.25
UNDERSCREEN CLEANER
Solvent The solvent pump supplies solvent to the paper roll from the external solvent
tank, mounted on the rear or either side of the machine. The external solvent
tank container is capable of accommodating a 5 litre container of solvent. A load
cell in the base of the external solvent tank enables the software to calculate
the percentage level of solvent within the container.
NOTE
1. In the event of the solvent container leaking, the volume of the solvent
container housing (8.329 ltr) is suffucient to hold the contents of the 5 ltr
solvent container.
2. The procedure to be followed in the event of a leaking sovent container is
detailed in the Preventive Maintenance section of this manual.
Solvent Advice The plastic tubing that transports the solvent from the solvent tank to the
underscreen cleaner head is designed to withstand most types of solvent.
However, mixing of two different solvents can cause a chemical reaction and
seriously damage the plastic tubing. When changing to a different type of
solvent, the tubing must be replaced completely to prevent solvent leaks. To
obtain new tubing and replacement instructions, order Machine Performance
Upgrade (MPU) 601187*2.
ASM only recommend the DEK-PRO XF (Environmentally Friendly) USC solu-
tion to be used with the under screen cleaner in this machine. The following are
available from ASM:
NOTE
The following solvents MUST NOT be used in the under screen cleaner unit,
however, this list is not complete and does not mean that any solvent not
mentioned is compatible, with DEK machines.
Rosstech 106 FE
Rosstech 162 ND
Acetone
Iso-Propyl Alcohol (IPA)
Description 1 Litre 5 Litre 20 Litre
DEK-PRO XF 431513 431514 -
TECHNICAL REFERENCE APPENDIX
PNEUMATIC MODULE
3.26 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
PNEUMATIC MODULE
Item Description Item Description
1 Machine Front Solenoids 4 External Connection
2 Filter, Regulator, Sensor and Gauge Assembly 5 Pneumatic Dump Valve
3 Venturi Vacuum Pump (Vacuum Tooling)
1
5
2
3
4
View on of MachineRear
TECHNICAL REFERENCE APPENDIX
PNEUMATIC MODULE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.27
The mains air supply should be supplied to the machine at a pressure between
5 bar and 7 bar.
The air should be to quality class 2.3.3, where:
2 (dirt) = 1 micron or less
3 (water) = -20°C pressure dew point
3 (oil) = 1mg/m³ or less
The mains air supply is filtered and regulated to 5 bar before being sensed by
the air pressure switch, which is set at 3 bar. The compressed air input is
applied to the following:
Machine Front Solenoids
Print Carriage Solenoids
Vacuum Tooling
Grid-Lok Tooling
Air Ionizer
The electrically activated solenoid valves provide pneumatic power through
several types of air cylinder.
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING OR DISCONNECTING ANY PNEUMATIC COMPONENTS, ENSURE
THE COMPRESSED AIR SUPPLY HAS BEEN DISSIPATED AND DISCONNECTED
FROM THE MACHINE.