222085 Issue 1 - Horizon APiX Appendix Manual.pdf - 第69页

TECHNICAL REFERENCE APPENDIX CALIBRATIONS 3.32 Appendix to Micron Technical Manuals Chapter Issue 1 June 15 NOTE During the squeegee pressure calibration the d well height of the rear squeegee is 15mm regardless of the s…

100%1 / 166
TECHNICAL REFERENCE APPENDIX
CALIBRATIONS
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.31
the following graphic:
14. Fit the calibration jig to the front squeegee position.
15. Fit the squeegee pressure plate to the rising table ensuring that the locating
dowels insert the holes of the rising table.
Mounting Plate
Mounting Holes
Calibration Jig
A
A
S
S
View on Front Squeegee MechanismUnderneath Rising Table and
View on Front of Rising Table and Squeegee Mechanism
Squeegee Pressure Plate
Locating Dowel
(in 2 positions)
O
OFF
I
ON
UNITS
Zero
MAX TXD
RESET
00.00
Portable Force Gauge
(Calibration Jig)
TECHNICAL REFERENCE APPENDIX
CALIBRATIONS
3.32 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
NOTE
During the squeegee pressure calibration the dwell height of the rear
squeegee is 15mm regardless of the set up value. This height is set during
calibration only.
16. Switch the force meter ON and check the reading is 0kg, (ensure the force
meter is not in contact with the squeegee pressure plate).
17. Select Continue.
18. The front squeegee mechanism steps down until a change in pressure is
detected and continues stepping down until the pressure value stored on the
machine is reached. If the calibration jig displays 10kg, go to Step 25.
19. Select Jog Rig.
20. Use the left and right jog buttons to move the front squeegee mechanism up
or down until the calibration jig displays 10kg.
NOTE
Achieving exactly 10kg may not be possible as some calibration jigs display
down to three decimal places.
21. Select Set Calib..
22. Select Exit.
23. The front squeegee mechanism moves to the home position. The message
‘Confirm that the pressure calibration jig has been removed.’ is dis-
played.
24. Remove the calibration jig and the squeegee pressure plate from the
machine. On completion select Yes, the table resets, the print carriage
moves to home position, board clamps open and the rear rail moves to the
board width setting.
25. Carry out the Squeegee Reference Height calibration.
Squeegee
Reference Height
Squeegee reference height is carried out on machines after the following
circumstances:
Squeegee pressure calibration
Squeegee change
Use the following procedure to set the squeegee reference height:
1. If a Ptest.dat file is not required, go to Step 7.
2. Select Maintenance.
3. Select Test Cycles.
4. Select Data Logging On.
5. Select Back.
6. Select Back.
7. Select Setup Product.
8. Select Squeegees.
9. Select Unload Screen.
10. Open the front printhead cover.
SEMI 2
TECHNICAL REFERENCE APPENDIX
CALIBRATIONS
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.33
11. Remove the screen from the machine.
12. Close the front printhead cover.
13. Press the System button.
14. Select Calibrate Heights.
15. The message ‘Ensure that the correct squeegees are fitted!’ is dis-
played.
16. If the correct squeegees are fitted, select Continue.
17. The following machine sequence is carried out:
a. The rails are checked for the presence of a board.
b. The rising table is driven to print height.
c. The board clamps are closed.
d. The print carriage drives the front squeegee over the front rail.
e. The rear squeegee is driven down to dwell height.
f. The front squeegee is driven down by the stepper motor until contact with
the board clamp is made.
g. The front squeegee continues to be driven down until a 2kg pressure
difference is detected, the motor pauses.
h. The amount of steps (the stepper motor took to get to this position) and
the pressure are recorded.
i. The stepper motor drives downwards another 15 steps, this is recorded
with the pressure detected. This is repeated a further 18 times to achieve
a total of 20 results.
18. The rear squeegee is calibrated in a similar manner.
19. The message ‘Calibrate Squeegee heights complete’ is displayed.
20. Select Back.
21. Select Back.
22. Select Maintenance.
23. Select Test Cycles.
24. Select Data Logging Off.
25. Select Back.
26. Select Back.
Ptest.dat File The file displays 20 front squeegee readings followed by 20 rear squeegee
readings, showing the relationship between steps (displacement) and pressure
applied. From the readings taken, the front and rear pressure factors and
squeegee reference heights are calculated. At the end of the file, 5 readings of
flood pressure and reference height readings are displayed (these are also
listed in the Config.txt file).
The Ptest.dat file is located on the hard drive of the machine PC. To view the
file carry out the following procedure:
1. From the Windows start menu, select Programs - Accessories - Windows
Explorer.