4 Machine - Calibrations
Service Manual Process Lens PL - 03/2025 145
Fig.213: Connecting the cables
(4) Loop the lighting cable from the right of
the lift table through the gap and over the
conveyor ball screw as shown. This will
prevent the cable from getting crushed
when the lift table is raised.
(5) Connect the lighting cable from the
machine to the target.
Step 5
Fig.214: “System test” tab
Click System Test (1).
At Utility, select One Point Dynamic Test
(3).
Click on Jogging (2).
Click on the directional arrows (4) to jog
the camera over to the target until the
square target comes into view.
Fig.215: Setting the lighting
At the Lighting Box menu (1), set 2D
Back lighting (2) to 25 and all other light-
ing values to0.
Click the centre (3) of the square target.
The camera centres the FOV to the
square target.
Step 6
Fig.216: Focus
Click on Focus icon (1).
Set value between 50~60 till image is
clear.
Click Continue (3) to proceed calibration.
4 Machine - Calibrations
146 Service Manual Process Lens PL - 03/2025
Step 7
Fig.217: Results displayed
Click Ok (1).
ð The results are displayed (2). The off-
set from the target should be ≤ 10μm in
both X and Y directions.
Click Ok (3).
Click Lift Down (4) to lower down lifting
table.
Click Open Door.
Disconnect the lighting cable and remove
the target.
4.4 Calibrations - Table Mapping
NOTICE
Mapping procedures for Single-lane Conveyor (ONLY) with option Left-Right or Right-Left has the
same procedures.
Left-Right Transport - input mapping plate from left
Right-Left Transport - input mapping plate from right
Preparation
This procedure compares the positions of the camera across the table (work area) against a target
glass plate mapped at a higher level of accuracy and compensates for the positional differences.
Fig.218: Process Lens PL [03139348S01]
4 Machine - Calibrations
Service Manual Process Lens PL - 03/2025 147
Fig.219: Process Lens PL HD [03251137-xx]
Prepare the coaxial light assembly. The Coaxial light consists of a lighting assembly(1) and a
cable(3). The glass surfaces are protected by a cover(2) secure by 2 screws.
Remove screws and the protective covers (2).
Clean the glass surfaces of the lighting assembly if necessary with a lint free cloth.
The Process Lens PL uses the SIPLACE SX-Series mapping plate version 5 (1). Each Mapping
glass plate has its own unique positional data map saved in a CD or in a Flash drive. The data is
in stored in a file named mp_mess.dat.
Open the mp_mess.dat file in the mapping CD or flash drive that comes with the mapping plate.
Compare the plate reference number (2) against the number labeled on the plate. They should
be the same.
4.4.1 Table Mapping: Teach
Step 1
Fig.220: “System test” tab
Go to the DiagnosticPage (1).
Click System Test (2).
Go to Utility, Table Mapping Calibration
(3).
Under Option, select Teach (4).
Click Start (5).