Retrofitting Instructions Flux Dispenser (Optional) on SIPLACE 80F
4
Edition 08/98
7
from
14
3.3 Installing the Flux Dispenser Head
3.3.1 Installing the Flux Dispenser Head
Fasten the dispenser head to the camera holder with 4 M5 x 12 socket head cap screws.
Exchange component illumination board Y0021 for component illumination board, flux, Y1033.
Remove the cover plate under the pump housing.
Connect X1 of the conversion board, flux, to X8 of the component illumination board, flux. Use the cable
“Flux monitoring, 00323903-01.
Connect X95 of the flux pump to X7 of component illumination board, flux. Use the cable “Control, flux
pump”, 00323902-01.
Re-install the cover plate.
Remove the U-shaped machine casing for conversion PC board C0003.
Plug the cable “V24 Flux” onto unused board slot X26, and run the other end through the machine base
to the control unit.
Slip the cable onto connector X4 of the communication module.
Re-install the U-shaped casing for the conversion PC board.
Flux Dispenser (Optional) on SIPLACE 80F
4
Retrofitting Instructions
Edition 08/98
Page
8
from 14
3.3.2 Tubing for Flux Dispenser Head
Run the long branch of the compressed air hose through the 2 holes in flux dispenser head
Loosen the clamping force on the pipette tube by backing the centering pipette out about 3 to 4
revolutions.
Insert the pipette tube into the dosing cylinder from the top.
Fasten the pipette tube in place by retightening the centering pipette. The pipette tube should project
about 3 mm.
Run the tubing for flux dispenser head as shown in Fig. 1.
Note
Run the tubes in such a manner that they cannot drag on the hood of the machine.
Figure 1 Flux Dispenser Head
Key to Fig. 1
Centering pipette ô Clamping piece
í Cylinder cover ÷ Dosing hose with pipette tube
û Valve and syringe ø Cylinder
Retrofitting Instructions Flux Dispenser (Optional) on SIPLACE 80F
4
Edition 08/98
9
from
14
3.3.3 Installing the Syringe on the Flux Dispenser Head
Insert the dosing piston into the syringe.
Screw the syringe into the valve with the retaining nut.
Pull the dosing piston down and fasten it in place with the knurled thumb screw.
Figure 2 Syringe
Key to Fig. 2
Knurled thumb screw ô Dosing piston
í Syringe ÷ Retaining nut
3.4 Installing the Rinsing Tank
Remove the IC head reject box.
Remove the reject box holder.
Install the new reject box holder with rinsing tank holder.
Insert a centrifugal tube into the rinsing tank holder.
Slip the brush onto the centrifugal tube.