Introduction Safety Instructions
7
– Safety Instructions
DANGER
Type and source of hazard
The safety instructions in the manual for the relevant SIPLACE X feeder module take precedence.
This instruction manual and the safety information within are targeted at use of the checking device and the
feeder module, separately from the machine .
Consequences
The "external feeder module power supply" is connected to the 230V AC (Europe) / 110V AC (USA); 50/60
Hz line power supply. When connecting to the 110V supply, you do not need to perform any conversions or
switch over the setting on the power pack.
Technical data for external power supply:
Power output:130 Watt
Input nominal current (max.): 3.2 A
Output nominal current (max.): 4.3 A
The "external feeder module power supply" must not be opened or manipulated.! (Danger of electric shock)
Consequences
Always observe the applicable accident prevention and VDE regulations, plus the specific safety regulations
for handling laboratory equipment and systems outside the machine, as applicable in your country.

Introduction Correct and Incorrect Use of the Testing Device
8
– Correct and Incorrect Use of the Testing Device
CAUTION
ESD
Before you perform any work on the feeder module control board, place an ESD wristband around your wrist,
to avoid causing damage through electrostatic discharge.
The checking device may only be modified or repaired by the manufacturer.
Always observe the warnings and safety instructions in the chapters of this manual.
In order to work safely with the testing and setting device, place it down on a suitably stable and solid table.
NOTICE
The testing device may only be used to test SIPLACE X feeder modules and may only be operated by spe
-
cially trained personnel.
Any other use of the checking device is understood to be incorrect and is therefore prohibited.