2 Retrofitting Instruct. S-23 HM t o SW V 502. xx incl. RV 6-DLM1 Head (O ption) SIPLACE S -23 HM 2.6 Required Tools, Auxiliary Test E quipment, etc. 07/01 Issue 76 2.5.8 Nozzle Changer f or 6-segment re volver head (opt…

100%1 / 126
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.5 Required Retrofitting Kits, incl. Software
75
2.5.5 Parts Needed in Case of an Existing 14" Monitor
-
15" monitor e156; touch screen Item no. 00357534S01
- Adapter e156 (incl. fasteners) Item no. 00357744S01
2.5.6 "6 C&P-head R-Configuration kit" (Option), Item no. 00117261-01
- Placement head assembly (RV 6-DLM1) Item no. 00354246-01 *)
- 3 Socket hex head cap screws M4 x 16
(to fasten the placement head)
- Head cover Item no. 00329003-01
(re-use the screws previously removed)
- 12 Nozzles Item no. 00326123-02
- 12 Nozzles Item no. 00326124-02
- 1 enclosed package/DLM1_S23 Item no. 00345365-03
1 Adapter plate, enclosed package S23 Item no. 00354836-01
1 Extension hose, vacuum, holding circuit_S23 Item no.00350975-01
1 Extension hose, vacuum, placement circuit_S23 Item no.00351031-01
1 Extension hose, interrogation, placement circuit_S23 Item no.00351032-01
4 Rubber-metal vibration buffers 15x30,
55 Shore D=15/H=30 Item no. 00345010-01
2 Velcro-type fastener Item no. 00346483-01
4 Cap screw M4x6 DIN6912 Item no. 00095105-01
4 Schnorr washer 4.3 V2a HN 160 Item no. 00342876-01
1 Conversion instructions DLM1 Collect & Place Head S23/F5 G+E 00191684-03
*) The 2 wide ribbon cables and the ribbon cable to the illumination board of the RV12-DLM1
head that were de-installed are to be re-used for the RV6-DLM1 head.
2.5.7 Spare Parts (not in the Kit but Required for 6-Segment Head, in Case of an
Defect)
- x- y- star axis board KSP-A362Item no. 00345516-02 *)
- z-dp- axis board KSP-A9362Item no. 00335519-04 *)
*) Required only in the event of an error in case one of the boards stops working during the
BIOS download.
2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option) SIPLACE S-23 HM
2.6 Required Tools, Auxiliary Test Equipment, etc. 07/01 Issue
76
2.5.8 Nozzle Changer for 6-segment revolver head (option)
Nozzle Changer for 6-segment revolver head (option), Item no. 00116162-01
2.5.9 Software LR UNIX, V 502.01
NOTE:
The line computer software V 502.01 is always required for this upgrade -> Item no.: see below.
Use the Software Version Description LRU V 502.01 for the installation. It also contains the re-
quirements for the UNIX line computer. 2
Software LR UNIX V502.01: Booting and installation disk and CD, Item no. 00358516-01.
2.6 Required Tools, Auxiliary Test Equipment, etc.
Set of Allen-type wrenches
Cross-slotted screwdriver, size 1
Screwdriver with internal serrations T8
Oblique-nosed cutting pliers (for removing cable ties while de-installing nozzle changer RV12)
Clean cloth and ethyl alcohol
CAN terminal with ribbon cable
Precision calibration case
Components for precision calibration
Mapping plates for PCB and revolver mapping
- 4 Cable ties (W = 2.4 mm, L = 92 mm) 00805140-01 per nozzle changer
- 2 Mounting pedestals for cable ties,
adhesive 00318666-01 per nozzle changer
- 1 (if necessary) adhesive label (with text) 00332920-03 German and English
- 1 (if necessary) adhesive label (with text) at request EU languages
- 1 (if necessary) adhesive label:
triangular warning
symbol, "Hand injury" 00335957-01
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.7 Required Documents
77
2.7 Required Documents
Software Version Description for Station V 502.01, Item no. 00192395-01 (G + E)
Software Guide SITEST V 502.xx, Item no. 00192656-01 (E)
Software version description, LRU V 502.01, Item no. 00192397-01 (G + E)
Technical Information No. 34V05060 *)
For the installation of options in connection with upgrading:
6-segment revolver head, modular:
Conversion instructions DLM1 Collect & Place head, Item no. 00191684-03 (G + E).
Setting instructions for SIPLACE S-25 HM, Item no. 00192192-02 (G + E)
Retrofitting instructions for MTC on S-25 HM, Item no. 00192792-02 (G + E)
Retrofitting instructions "Head board, modular, Item no. 00192919-01 (G + E) -> in
progress,
Partial information, e. g., photos, Item nos. PCBs
, new cables required, etc. -> see: retro-
fitting instructions "PCB camera Multicolor..." (below)
Retrofitting instructions
"PCB camera Multicolor on S-25 HM and HS-50", Item no. 00192232-01 (G + E);
-> Requirement: Retrofitting of the modular head boards at both gantries.
*) ATTENTION: This documentation is intended for INTERNAL use only.
When finished, put the documentation back with your papers.
NOTE:
These instructions contain the retrofitting of the nozzle changer RV6 Standard (for 6-segment re-
volver head DLM1) (see: Section 2.8.8). 2