00196744-01 - VD SIPLACE Explorer 2.7_de_en.pdf - 第22页

Softw are Vers ionsbes c hreibung Softw are Vers ion Des cr iption SIPL ACE Ex plo rer V2.7 22 von 56 1. Dif ferences i n stat us mo dels an d t hei r states: OI S has a st atus model for each of t he two proc essing are…

100%1 / 56
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
21 of 56
If you start an OIS query via SQL Query, for the time between T1 and T2, the result will show the total
number of components which were placed on all 8 boards minus the number of components which were
placed on board 1 of placement area 1.
If you start the same query via SIPLACE Explorer, the result will show the total number of components
which were placed on all 8 boards.
In this example, the result in SIPLACE Explorer will be higher than the number shown in OIS.
However, this is not always the case. If board 9 is placed (in placement area 1 in the diagram), SIPLACE
Explorer will not count the components which were placed on this board and will therefore show fewer
components as the OIS.
For this reason, there will also be deviations between OIS and SIPLACE Explorer in the determination of
component reject numbers.
5.7 Status Display Deviations Between SIPLACE Explorer and OIS
There is a special OIS status module realized in SIPLACE OIS. This OIS status module is shown in the
SIPLACE Explorer status module which matches the SEMI E10 status module. This may lead to
deviations in the states and status times shown between OIS and SIPLACE Explorer. A direct
comparison is therefore not possible.
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
22 von 56
1. Differences in status models and their states:
OIS has a status model for each of the two processing areas but no status model for the entire machine.
SIPLACE Explorer, on the other hand, does have a status model for the whole machine (E10).
OIS recognizes the following 5 states:
Running
Starved
Blocked
Interrupted, fault
There are no substates.
The E10 status model in SIPLACE Explorer recognizes the following 6 states:
Productive
Standby
Engineering
Scheduled Downtime
Unscheduled Downtime
Nonscheduled Time
There is also a special status Unknown.
Many of these states have substates, such as:
The status Productive has the following substatus:
o Zone1Productive_Zone2Productive, Zone1Productive_Zone2Blocked
o Zone1Blocked_Zone2Productive, Zone1Productive_Zone2Starved
o Zone1Starved_Zone2Productive.
The OIS states can not be shown by the SIPLACE Explorer E10 status.
2. Differences between machines with two processing areas:
Since OIS does not have a status model for the entire machine (just one for each processing area),
although it should shown the times for each status (Running, Starved, Blocked, Interrupted and Fault) for
the whole machine, the times for both status models are only taken into account to 50% each by the
status display for the machine.
This means that, if an X4 machine places one board for one minute in processing area 1 and then places
for another minute in processing area 2, the machine should show 50% of the time in the status Place
and 50% in the status Starved, provided a board is placed into the machine every two minutes.
Software Versionsbeschreibung Software Version Description SIPLACE Explorer V2.7
23 of 56
In contrast, SIPLACE Explorer has a status model for the whole machine and determines at any one time
a status which relates to the entire machine. If only one processing area places at any one time, while the
other waits, this will be shown by the substate Zone1Productive_Zone2Starved and
Zone1Starved_Zone2Productive. These substates are shown in the status Productive. In the above
example for the X4 machine, SIPLACE Explorer will show the status Productive during board placement.
If the user wants to see whether a different processing area is waiting, he must switch over to view the
substate.
3. Taking into account stations which are switched off or not accessible via the network:
In OIS, stations which are switched off or not accessible via the network do not lead to a new status.
In SIPLACE Explorer, stations which are switched off or not accessible via the network are assigned
special substates (e.g. "Scheduled downtime – Other“, "Unscheduled downtime – Power down" or
"Nonscheduled time – Power down").
4. Status "Unknown" in SIPLACE Explorer:
If SIPLACE Explorer is unable to reach the OIS database via the network, SIPLACE Explorer will show
the status "Unknown". This status is not recognized by OIS.
5. Times taken into account during a period of observation:
OIS only takes into account those times during the period in which the station sends events.
The SIPLACE Explorer E10 status always considers all time in the set period.
Example: The shift begins at 6 a.m. and it is now 1 p.m. The station sent events during the period 6:30 to
12:30. The total time taken into account by OIS is 6 hours (e.g. 5 h Running, 40 min Starved and 20 min
Blocked). The SIPLACE Explorer E10 automatic status function also defines states for the times in which
the station did not send events (e.g. the status "Unscheduled Downtime – Power Down" from 6:00 to
6:30 and from 12:30 to 13:00 hours). The total time considered by the SIPLACE Explorer E10 status
model is therefore 7 hours.
6. Status "Other" on the SIPLACE Explorer website "Performance":
On the SIPLACE Explorer website "Performance", 5 OIS states are shown. There are also the two states
"Other" and "Unknown", which OIS does not recognize. The status "Other" (shown in brown) contains the
states "Scheduled Downtime" and "Nonscheduled Time" of the E10 state model.