EUKYX 2-12 199-2100 3.1 Common SET ( B 01_ 01 ) PCB size X (Horizont al) , Y ( V er tical) , an d T (thickness) [ mm] Set the dimens ions of the PCB to be produced. Y (V ertical) T (Thickness) PCB X (Horizontal) PCB Flow…

100%1 / 327
EUKYX
2-11199-2100
3.1 Common SET
3. Explanation of Pattern Program
In this instruction manual, the placement coordinate reference is based on “Front Right”.
3.1 Common SET
This data is used in the dual transfer operation (option).
3.2 PCB
(B01) PCB Data
Graphic
Development
F2B3
Note
EUKYX
2-12199-2100
3.1 Common SET
(B01_01)
PCB size
X (Horizontal), Y (Vertical), and T (thickness) [mm]
Set the dimensions of the PCB to be produced.
Y (Vertical)
T (Thickness)
PCB
X (Horizontal)
PCB Flow Direction
F2B4
When the PCB has a cutout, the following dimensions must be entered.
Y (Vertical)
T (Thickness)
PCB
X (Horizontal)
PCB Flow Direction
F2B5
Data Input Range
X : 50 to 610
Y : 50 to 510
T : 0.3 to 5.0
(a) Be sure to set a correct parameter in the "X (Horizontal)" text box because the set
parameter is used to automatically correct the placement position when a parameter is
selected in the "PCB locate method" text box in the "PCB transfer Mode Setup" tab sheet.
(b) The set parameter in the "Y (Horizontal)" text box must be used as a target width for the
conveyor width automatic adjustment operation.
(c) "T (Thickness)" is used as a target value for the backup table ascending position when a
PCB is clamped by the clamp plates and positioned.
Note
EUKYX
2-13199-2100
3.1 Common SET
(B01_02)
PCB origin offset
X (Horizontal), Y (Vertical) [mm]
Set the offset values to correct the difference between the placement coordinate reference (N0) and
the PCB origin (P0).
"Plus" or "Minus" can be set in both X and Y coordinates in the direction of the correction.
Placement Coordinate Reference Point :
For Front Right
Y
PCB Origin(P
0)
PCB
X
Placement Coordinate Reference (N0)
PCB Origin(P0)
Y
X
Placement Coordinate Reference (N0)
X
Y
PCB
PCB Origin(P
0)
Placement Coordinate Reference (N0)
Y
X
PCB
PCB Origin(P
0)
Placement Coordinate Reference (N0)
Placement Coordinate Reference Point :
For Rear Left
Placement Coordinate Reference Point :
For Front Left
Placement Coordinate Reference Point :
For Rear Right
PCB
+
+
+
+
+
+
+
+
F2B6
Z (Angle) [deg]
Set the offset value for component placement angle.
The set value is added to the “Offset Z (deg)” of all components in the placement data (P data).
To correct the angle of component placement counterclockwise, a parameter must be entered with
a plus (+) sign. A minus (-) sign must be affixed for clockwise correction.
F2B7