00196390-0102.pdf - 第33页

Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3 10/2008 Edition 33 : Loosen the screws for cable attachment and unpl ug the four vision cables. 2 2 : Unscrew the screws for the met al frame with wh…

100%1 / 54
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
32
: Glue a piece of adhesive tape directly onto the clamp around the ribbon cables and the protec-
tive band but not around the compressed air hoses. The adhesive tape serves to fix the ribbon
cables together and to mark the position in the clamp.
2
2
: Fix the ribbon cables and the protective band with a second adhesive tape in order to prevent
slipping between them and to ensure, during later assembly, that the distances between the
cables are maintained between each other.
2
Adhesive
tape
Adhesive tapes
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
33
: Loosen the screws for cable attachment and unplug the four vision cables.
2
2
: Unscrew the screws for the metal frame with which the ribbon cable connectors are secured.
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
34
: Remove the metal frame.
2
2
: Unplug all ribbon cable connectors.
2
Remove the
metal frame