Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3 10/2008 Edition 46 : Lay a new pressure plate under th e hose band in the clamp on the gantry . 2 : Glue two of the clamping plates again onto bo th …

100%1 / 54
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
45
: Insert the plug-in nipples for the new hose band into the existing hoses on the gantry and press
them in firmly using the hose pliers.
2
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
46
: Lay a new pressure plate under the hose band in the clamp on the gantry.
2
: Glue two of the clamping plates again onto both metal clips of the clamp with the aid of the
double-sided adhesive tape.
: Lay one of these clamping plates with a metal clip onto the sevenfold hose and screw down
the package firmly as shown in the picture (4 screws). The screws must be secured using Loc-
tite 241.
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
47
: Screw down the four inner screws tightly cross-wise using a torque of 0.7 +/- 0.2 Nm and then
coat them with lacquer.
Mark the clamp on the upper side with a green point.
In this way one can recognize later whether new pressure plates have been installed.
2
2
: Loosen the topmost adhesive tape.
2