00196390-0102.pdf - 第38页

Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3 10/2008 Edition 38 : Loosen the lacquered screws by one tur n. They will be tightened la ter again with torque. 2 2 : Carefully push the bigger Plexi…

100%1 / 54
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
37
: Measure the length of the sevenfold hose between the clamps and note the dimension.
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
38
: Loosen the lacquered screws by one turn.
They will be tightened later again with torque.
2
2
: Carefully push the bigger Plexiglas plate between the clampings on the gantry between ribbon
cable and the hose band.
2
2
2
Loosen
lacquered
screws by
one turn
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
39
: Lay the second Plexiglas plate on the hose band.
: Cut the hose band along the Plexiglas template using a knife.
2
2
2
2
2
2
2
2
2