Host Computer System.pdf - 第103页
AVK3 HOST COMPUTER SYSTEM 3.10 Upl oadi ng Rotary Chuck Inf ormati on D77HEC-54- 090-A0 3.10- 4 Protocol Condition Vali d i n O NLINE m ode only . Af ter receiv ing ‘A2’ from H O ST, the processing ends. Star t o…

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-3
1) -5
D0FnTnnnnnnnnnnEnnnnnnnnnnInnnnnnnnnn
1 2 3 4 5
Pnnnnnnnnnn
RnnnnnnWn
6 7 8
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1
52 mm chuck
command
1
×
Output command for the 52
mm rotary chuck information
2 Chuck No. 1 1 to 4
×
3
Parts chuck
count
10 0 to 999999999
×
4
Insertion error
count
10 0 to 999999999
×
5
No. of insertion
points
10 0 to 999999999
×
6
Parts remove
count
10 0 to 999999999
×
7 Insertion rate 6 0 to 100000
×
1 / 1000% increments
8
Maintenance
warning
1 0 to 1
×
0 = Insertion rate more than
99.01
1 = Insertion rate less than
99.00

AVK3
HOST COMPUTER SYSTEM
3.10 Uploading Rotary Chuck Information
D77HEC-54-090-A0
3.10-4
Protocol
Condition
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
Start of upload
Host computer
Sends out rotary chuck
information.
AVK3
D 0 Collection start date
A 0
D 0
Collection end date
Requests next data.
A 0
A 0
D 0
∗
A 2
End of reception
End of transmission
C1R Total designation
A 0
D 0
Rotary chuck information
Sends out rotary chuck
information.
Sends out rotary chuck
information.
Requests next data.
Requests next data.
Sends out EOP data.

AVK3
HOST COMPUTER SYSTEM
3.11 Uploading NC Program Directory
D77HEC-54-100-A0
3.11-1
3.11. Uploading NC Program Directory
D77HEC-54-100-A0
3.11.1 Uploading NC Program Directory
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal NC program directory and then can read the NC program directory (using C1 command) sent to the
AVK3.
Data details
AVK3 ⇒ Host computer
1) -1
D0yyyy / mm / ddyyyy / mm / ddPxxx∗ ~ ∗
1 2 3
No. Data name
Max.
digits
Input range
Sup-
press
Fix Remarks
1 Registered date
10
(/ included)
×
yyyy = Year (AD)
mm = 01 to 12
dd = 01 to 31
2 Changed date
10
(/ included)
×
yyyy = Year (AD)
mm = 01 to 12
dd = 01 to 31
3 Program name 16
× ×
f the characters of the control
No. and name are less than
16 digits, output will be up to
the registered length.
STX
C 1 Z x
No. of
characters
ETX
x x
Check sum
STX
D 0
No. of
characters
ETX
Check sum
1) -1