Host Computer System.pdf - 第111页
AVK3 HOST COMPUTER SYSTEM 3.14 Upl oadi ng Parts Data Direct ory D77HEC-54- 130-A0 3.14- 2 Protocol Condition Vali d i n O NLINE m ode only . Af ter receiv ing ‘A2’ from H O ST, the processing ends. Di rect ory…

AVK3
HOST COMPUTER SYSTEM
3.14 Uploading Parts Data Directory
D77HEC-54-130-A0
3.14-1
3.14. Uploading Parts Data Directory
D77HEC-54-130-A0
3.14.1 Uploading Parts Data Directory
With AVK3, if host computer gives C1 command to AVK3, the AVK3 becomes the receiving mode of the
internal parts data directory and then can read the parts data directory (using C1 command) sent to the
AVK3.
Data details
AVK3 ⇒ Host computer
1) -1
D0yyyy / mm / ddD∗ - ∗
1 2
No. Data name
Max.
digits
Input range
Sup-
press
Vari-
able
Remarks
1 Changed date
10
( / included)
×
yyyy = Year (AD)
mm = 01 to 12
dd = 01 to 31
2 Program name 16
× ×
If the characters of the control
No. and name are less than
16 digits, output will be up to
the registered length.
STX
C 1
No. of
characters
ETX
Check sum
S
STX
D 0
No. of
characters
ETXCheck sum
1) -1

AVK3
HOST COMPUTER SYSTEM
3.14 Uploading Parts Data Directory
D77HEC-54-130-A0
3.14-2
Protocol
Condition
Valid in ONLINE mode only.
After receiving ‘A2’ from HOST, the processing ends.
Directory information will be output as many as the number of registered directories.
Start of upload
Host computer
Sends out directory
information.
AVK3
D 0 Directory information
A 0
C1S
D 0
Directory information
Requests next data.
A 0
Requests next data.
Sends out directory
information.
Sends out EOP data.
A 0
D 0
∗
A 2
End of reception
End of transmission

AVK3
HOST COMPUTER SYSTEM
4. MONITORING
D77HEC-55-AA0-A0
4-1
4. MONITORING