00196775-0102_OM_DockingStation_SX_EN.pdf - 第29页
25 Docking Station for SIPLACE SX Changeover Tables 4 Operation Operating Manual 4.2 Adjusting the Conveyor Height 4.2 Adjusting the Conveyor Height Flat spanners of size SW 22 and SW 24 and a spirit level are required. …

4 Operation Docking Station for SIPLACE SX Changeover Tables
4.1 Controls and Indicators Operating Manual
24
4.1.1 CAN Bus Addresses
The CAN bus addresses that can be set are indicated on the sticker located below the switches
S1 and S2.
Fig. 4 - 2 CAN bus addresses

25
Docking Station for SIPLACE SX Changeover Tables 4 Operation
Operating Manual 4.2 Adjusting the Conveyor Height
4.2 Adjusting the Conveyor Height
Flat spanners of size SW 22 and SW 24 and a spirit level are required.
2
1
Fig. 4 - 3 Adjusting the conveyor height
(1) 2x lock nut SW 24
(2) 1x adjusting screw SW 22
To adjust the conveyor height, proceed as follows:
1. Loosen the lock nuts on all adjusting feet.
2. Use the adjusting screws to adjust the dimension Y (see table).
3. Check that the machine is horizontal (ûsing the spirit level).
Machine height Dimension X Dimension Y Dimension Z
900 mm 859 mm 100 mm 770 mm
930 mm 889 mm 130 mm 800 mm
950 mm 909 mm 150 mm 820 mm

4 Operation Docking Station for SIPLACE SX Changeover Tables
4.3 Docking and Undocking the Changeover Table Operating Manual
26
4.3 Docking and Undocking the Changeover Table
2
1
Fig. 4 - 4 Docking station for SIPLACE SX
(1) Pneumatic cylinder for locking the changeover table
(2) Sensor for changeover table detection
4.3.1 Docking the SIPLACE SX Changeover Table to the Docking Station
WARNING
Do not reach between the areas between the changeover table and the docking station during
docking.
– Push the changeover table into the docking station until it is locked by the pneumatic cylinders.
– The two buttons will flash shortly. If the changeover table is properly locked, the white button
(changeover table release) will be lit permanently.
– If the changeover table is not locked properly, the white button will be flashing.
– If the feeders are locked properly, the green feeder locking button will be lit.