TRS GEM Manual for Intel Ver 1.1.pdf - 第108页
GEM Manual for DEK P rinters Equipment Variables Issue 1.1 March 20th, 2014 Page 108 of 152 Page 108 of 152 Name SVID Lim its Monito r Description Type Value Range screen_status 1024 No The position of the screen in the …

GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 107 of 152 Page 107 of 152
7.3 Status Variables
The status variables are defined in the table below:
Name
SVID
Limits
Monitor
Description
Type
Value Range
GemAlarmsEnabled
1001
No
List of alarms that are enabled.
List
A list of “n” ALID’s.
GemAlarmsSet
1002
No
List of alarms that are set.
List
A list of “n” ALID’s.
See chapter 6 for ALID’s.
GemAlarmState
1003
No
State of last alarm transition.
U1
0 = OFF
1 = ON
clock
1004
No
Host view of equipment time.
(centisecond precision)
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
GemControlState
1005
No
Current GEM Control State.
U1
1 = Equipment Off-Line
2 = Attempt On-Line
3 = Host Off-Line
4 = Local
5 = Remote
process_state
1006
No
Current Equipment Process State.
U1
0 = Equipment Ready
1 = Equipment Waiting
2 = Equipment Running
3 = Equipment Setup
4 = Equipment Down
5 = Equipment Recovery
6 = Equipment Maintenance
GemEventsEnabled
1007
No
List of collection events enabled.
List
A list of “n” CEID’s.
See chapter 7.
humidity
1008
Yes
Current humidity in print area.
F4
0-100 %
model_number
1009
No
Model number.
A6
String
previous_command
1010
No
Last command received from operator
or host.
A
See appendix A.
GemPreviousControlState
1011
No
Control state prior to last transition.
U1
See GemControlState.
last_process_state
1012
No
Process state before last transition.
U1
See process_state.
GemPreviousCeid
1013
No
CEID of last collection event to occur.
U4
See chapter 7.
Reserved
1014
No
software_version
1015
No
Software revision 6 char ASCII.
A6
See chapter 4. (SOFTREV)
temperature
1016
Yes
Current temperature in the print area.
F4
0 -100 (Celsius)
current_time
1017
No
Host view of equipment time.
(1 second precision)
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
system_mode
1018
No
The current machine mode.
U1
0 = Step
1 = Auto
2 = Single
3 = No Print
PPExecName
1019
No
Name of current process program.
A68
batch_count
1020
Yes
Number of Boards printed.
U4
0-99999
Reserved
1021
No
time_last_print
1022
No
Time of the last print.
A12/
A16
Yymmddhhmmss/
Yyyymmddhhmmsscc
spc_data_mode
1023
No
Reporting mode of the SPC.
U1
0 = Serial
1 = Disk
2 = Invalid
3 = None

GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 108 of 152 Page 108 of 152
Name
SVID
Limits
Monitor
Description
Type
Value Range
screen_status
1024
No
The position of the screen in the
printer chase.
U1
1 = No screen.
2 = Screen loaded.
3 = Unloaded at front.
4 = Unloaded at rear.
5 = Screen in chase, but not
loaded.
software_version_param
1025
No
The software version to be stored in
the process program file that indicates
the version of software that last
modified the file.
A20
SSS Version MM.mm
SSS = Source machine type.
MM = Major version level.
mm = Minor version level.
SpoolCountActual
1026
No
Used to keep a count of the messages
actually contained in the printer's
spool area. Multi-block inquire/grant
messages are not
spooled and not included in this count.
U4
0 to 2000 (absolute maximum)
SpoolCountTotal
1027
No
Used to keep a count of the total
number of primary messages directed
to the spool, regardless of whether
placed or retained in the
spool. Multi-block inquire/grant
messages are not spooled and not
included in this count.
U4
0 to 0xFFFFFFFF
SpoolFullTime
1028
No
Contains the timestamp from the time
the spool last became full. If the spool
was not filled during the last spooling
period, this will contain a time value
prior to the current SpoolStartTime.
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
SpoolStartTime
1029
No
Contains the timestamp from the time
spooling last became active.
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
Reserved
1030 -
1049
Not used by the 265.
PPChangeName
1050
No
The name of the last process program
changed (created, modified or deleted)
A68
PPChangeStatus
1051
No
The change operation last performed
A20
PPError
1052
No
Details of any failed product
validation after up/download
A68
PPFormat
1053
No
The format of DEK process programs
U4
Always 1 - Unformatted

GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 109 of 152 Page 109 of 152
7.4 Discrete Data Variables
The discrete data variables are defined in the table below:
Name
DVID
Limits
Monitor
Description
Type
Value Range
GemAlarmId
2001
No
Identity of alarm transition.
U4
See chapter 6.
pp_old_file_name
2002
No
Name of process program being
changed.
A68
Any characters valid in a
Windows filename.
pp_change_status
2003
No
Type of process program change.
U1
1 = Load process program
2 = Rename process program
3 = Erase process program
measured_cycle_time
2004
Yes
The duration in seconds of the
most recent machine cycle.
F8
0 = no data
to 3.2 million seconds
throughput_cycle_time
2005
Yes
The average duration in seconds of
the machine cycle time. Averaged
over the last 1 to 50 cycles.
F8
0 = no data
to 3.2 million seconds
Reserved
2006
No
ecid_changed
2007
No
VID of changed equipment
constant.
U4
front_print_pressure
2008
Yes
Front squeegee pressure of last
cycle.
F8
0-20 Kg
rear_print_pressure
2009
Yes
Rear squeegee pressure of last
cycle.
F8
0-20 Kg
print_speed
2010
Yes
Speed measured during the last
print stroke.
F8
2-150 mm/s
table_separation_speed
2011
Yes
Speed of board and screen
separation measured during last
print cycle.
F8
0.1-20 mm/s
board_stretch_error
2012
Yes
Difference between board and
screen fiducials measured after the
print cycle.
F8
5.0 mm
Xerr
2013
Yes
X alignment accuracy.
F8
0.025 mm
Yerr
2014
Yes
Y alignment accuracy.
F8
0.025 mm
theta_err
2015
Yes
Theta alignment accuracy.
F8
arcsec
Squeegee
2016
No
Squeegee used to perform the last
print.
U1
0 = No action.
1 = Front squeegee.
2 = Rear squeegee.
current_screen_bar_code
2017
No
The barcode of the current screen
as scanned when the screen was
loaded.
The default is “NO CODE”.
A32
Up to a 32 character string.
The actual length is
determined by the barcode.
old_time
2018
No
The previous value of the clock
before it was last changed.
A12
A16
Yymmddhhmmss
Yyyymmddhhmmsscc
new_time
2019
No
The time that the clock was last
changed.
A12/
A16
Yymmddhhmmss
Yyyymmddhhmmsscc
product_bar_code
2020
No
The most recent barcode scanned
by the product barcode reader. The
default is “NO CODE”.
A32
Up to a 32 character string.
The actual length is
determined by the barcode.
board_fiducial_1_score
2021
Yes
The acceptance score of board
fiducial 1.
U4
0-1000
board_fiducial_2_score
2022
Yes
The acceptance score of board
fiducial 2.
U4
0-1000
board_fiducial_3_score
2023
Yes
The acceptance score of board
fiducial 3.
3 fiducial mode must be selected.
U4
0-1000
screen_fiducial_1_score
2024
Yes
The acceptance score of screen
fiducial 1.
U4