TRS GEM Manual for Intel Ver 1.1.pdf - 第6页
GEM Manual for DEK P rinters GEM Compliance State ment Issue 1.1 March 20th, 2014 Page 6 of 152 GEM Complianc e Statement The following tables show the f undamental requirements and a dditional capabilities implemented o…
GEM Manual for DEK Printers Introduction
Issue 1.1 March 20th, 2014 Page 5 of 152
Introduction
GEM compatible screen printers manufactured by DEK Printing Machines Ltd. are capable of
operating in co-operation with automatic loading systems and factory hosts. In this manual the
screen printer is referred to as the “equipment”.
This manual describes the host view of the GEM compliant interface provided with the system.
A detailed description of the equipment capabilities is followed by the implemented SECS II
streams and functions list.
The machine variables, alarms and event messages are then listed to enable remote process
control to be achieved.
References:
SEMI E4-91 - SEMI Equipment Communications Standard 1 Message Content (SECS-I)
SEMI E5-96 - SEMI Equipment Communications Standard 2 Message Content (SECS-II)
SEMI E30-95 - The GEM Standard
SEMI E37-0303 – High-Speed SECS Message Services (HSMS) Generic Services
SEMI W39-0703 – Object Services Standard: Concepts, Behaviour and Services
To order the SEMI Publications, contact:
SEMI,
Dept. 05607,
San Francisco,
CA 94139

GEM Manual for DEK Printers GEM Compliance Statement
Issue 1.1 March 20th, 2014 Page 6 of 152
GEM Compliance Statement
The following tables show the fundamental requirements and additional capabilities
implemented on this equipment.
Fundamental GEM Requirement
Implemented
GEM compliant
State models
Yes
Yes
Equipment processing states
Yes
Yes
Host Initiated S1F13/14 scenario
Yes
Yes
Event notification
Yes
Yes
On-Line identification
Yes
Yes
Error messages
Yes
Yes
Documentation
Yes
Yes
Control (operator initiated)
Yes
Yes
Additional Capabilities
Implemented
GEM compliant
Establish communications
Yes
Yes
Dynamic event report configuration
Yes
Yes
Variable data collection
Yes
Yes
Trace data collection
Yes
Yes
Status data collection
Yes
Yes
Alarm management
Yes
Yes
Remote control
Yes
Yes
Equipment constants
Yes
Yes
Process program management
Yes
Yes
Material movement
Yes
Yes
Equipment terminal services
Yes
Yes
Clock
Yes
Yes
Limits monitoring
Yes
Yes
Spooling
Yes
Yes
Control (host initiated)
Yes
Yes

GEM Manual for DEK Printers Machine GEM Compliance
Issue 1.1 March 20th, 2014 Page 7 of 152
Machine GEM Compliance
GEM Requirement
Equipment Constants (ECIDs)
GemConfigConnect (ECID 1)
DeviceName (ECID 2)
GemEstabCommDelay (ECID 3)
GemPollDelay (ECID 4)
GemInitCommState (ECID 5)
GemInitControlState (ECID 6)
GemOfflineSubstate (ECID 7)
GemOnlineFailed (ECID 8)
GemOnlineSubstate (ECID 9)
received_mode (ECID 10)
inspect_rate (ECID 11)
batch_limit (ECID 12)
process_adjustments (ECID 13)
MaxSpoolTransmit (ECID 14)
OverWriteSpool (ECID 15)
spooling_enabled (ECID 16)
TimeFormat (ECID 40)
RunGEMRemote (ECID 41)
CompoundProductFiles (ECID 46)
Make (ECID 50)
Model (ECID 51)
Reserved (ECID 52)
StencilCleaningSystem (ECID 53)
ApplicatorType (ECID 54)
ConveyorType (ECID 55)
TransportMode (ECID 56)
MachineUnits (ECID 57)
UplineProtocol (ECID 58)
DownlineProtcol (ECID 59)
TransferPeriod (ECID 60)
PasteDispensePosition (ECID 61)
ToolingHardware (ECID 62)
FiducialReference (ECID 63)
ProductBarcodeHardware (ECID 64)
RemoteBarcodeHardware (ECID 65)
AdvancedProFlow (ECID 66)
PressureHardware (ECID 67)
PasteDispenser (ECID 68)
ScreenSize (ECID 69)
RollHeightHardware (ECID 70)
RollHeightMonitor (ECID 72)
ConsumableAction (ECID 73)
VacuumHoldTime (ECID 74)