manual-fae1-fume-extractor-0032497_ID-241531_EN.pdf - 第15页

FR ONT - + 15 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm par a manuales - c olor g r is 200 mm 300 mm Quick Release Lever Adjustment - Turn clockwise to loosen and counterclockwise to tighten, in order to adjust the fil…

100%1 / 20
FRONT
Maintenance and Filter Replacement
- The fume extractor unit indicates by means
of display and LED’s that the fi lters need to
be replaced.
- To replace the fi lters remove the cover (1) by
opening the quick release levers (2), located
on both sides of the casing.
- If the indicator LED (3) remains in red after
replacing the pre-fi lter (4), it means that the
main fi lter (5) is saturated and must also be
replaced (see fi gure below) (6).
- After replacing the main fi lter (5), the carbon
fi lter counter must be reset (Main Menu >
Filter Set > Reset Carbon).
- The service life of the maint fi lter is
a maximum of 1 year after opening its
packaging.
- If the fi lter is changed while the fume
extractor is switched on, the fume extractor
unit automatically starts the fi lter detection
process and activates the aspiration for a few
seconds.
Cover
Indicator LED
Pre-Filter
Main Filter
(carbon + HEPA)
Connect the fi lter tube to the
quick-coupling placed on the metal
sheet
Note: The main fi lter has a given
position. Make sure the fi lter ribs
mate with the corresponding slots.
Quick Release
Lever
Filter
Ribs
Casing
1
2
3
4
5
2
6
14
FRONT
-
+
15
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
Quick Release Lever Adjustment
- Turn clockwise to loosen and counterclockwise to tighten, in order to adjust the filter airtightness.
Read the safety guidelines to do the equipment maintenance safely.
Accessories
FAE1110
Pre-Filter for FAE1
medium dust filter M5
(EN 779)
FAE1100
Filter for FAE1
Compact Filter
active carbon filter and
particle filter HEPA H13
(EN 1822)
Safety
- The equipment is designed to filtrate only the fumes generated by soldering.
- Do not use the units for the filtration of combustible, explosive or corrosive gases. Incorrect use may
cause fire.
- The power plug must be plugged into approved bases. Be sure that it is properly grounded before use.
When unplugging it, hold the plug, not the wire.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause flammable products to ignite.
- This appliance can be used by children over the age of eight and persons with reduced capabilities or
lack of experience provided that they have been given adequate supervision or instruction concerning
use of the appliance and understand the hazards involved.
- Maintenance must not be carried out by children unless supervised.
- Keep your workplace clean and tidy. Wear appropriate protective mask, safety googles and gloves
when handling polluted filters or pre-filters.
- Do not use the equipment without the fi lters.
- Saturated filters can not be cleaned and reused.
- Avoid blowing out the fi lter or the dirty parts of the equipment, if necessary it is recommendable to
vacuum them.
- When handling the fi lter, avoid losing particles from the fi lter.
- Treat the saturated filters as waste depending on the filtered contaminant and the applicable standards
in each country. This is the European Waste Catalogue classification:
15 02: Absorbents, filter materials, wiping cloths and protective clothing.
15 02 02: Absorbents, filter materials (including oil filters not otherwise specified), wiping cloths,
protective clothing contaminated by dangerous substances.
15 02 03: Absorbents, filter materials, wiping cloths and protective clothing other than those mentioned
in 15 02 02.
- In case of not complying with the filter change recommendations, the maximum particle and gas
concentrations established in each country could be exceeded.
Follow safety guidelines to prevent electric shock, injury, fire or explosion.
16