ap-az9502-high-frequency-ac-ionizing-air-nozzle-new.pdf - 第9页

The AP-AZ950 2 High-Frequency Ionizing Nozzle under goes rigorous testing, inspec tion, and high-temperatu re aging processes before leaving the factory, and its performance fully meets the relevant indicators stated in …

100%1 / 11
If wiring is required, please refer to the wiring information table for connection operations:
3
Adjust the throttle valve of the air connector; the gas pressure should be < 0.5MPa, with the optimal gas
pressure being 0.3MPa.
After powering on, ionized gas will be emitted from the nozzle of the air nozzle. If the power-on indicator and
operation indicator on the air nozzle are lit green, it indicates normal operation and electrostatic elimination is
in progress.
The outlet of the ionizing air nozzle should be vertically aligned with the surface of the object to be neutralized of
static electricity, with an optimal distance of approximately 150mm to 300mm.
The compressed air used should be dry and clean.
5
6
7
4
AP-AZ9502-485 AP-AZ9502-IO
Function information of the RJ45 interface cable
1 Orange +24VDC +24VDC
2 White Orange +24VDC +24VDC
3 Blue RS485+B /
4 White Blue RS485+A Input 0V: Ionizer pauses operation
5 Green 0VDC 0VDC
6 White Green 0VDC 0VDC
7 Brown HV
AL
High Voltage Abnormal HV
AL
High-voltage fault
8 White Brown
ACT:Static Eliminator Power-on Indication /
Clean:Static Eliminator Cleaning Indication /
9 Metal Shield PE PE
As shown in the figure above, sequentially remove the stainless steel nozzle head and the ceramic protection
tube from the ionizing air nozzle outlet. Observe the exposed alloy electrode; if it appears rounded or blunt,
it should be replaced to ensure the effectiveness of static elimination.
If the green power-on indicator on the air nozzle body goes out or the red alarm indicator lights up, stop
using it. It can only be used again after professional maintenance personnel have checked the circuit or
repaired the air nozzle.
If there is leakage in the air supply hose or throttle valve, check the assembly and connection. If damaged,
replace them promptly to ensure normal air supply pressure.
The alloy electrode in the nozzle part of the air nozzle is a consumable item and is not covered by the
warranty. If replacement is required during maintenance, it will be charged.
Hook Alloy Discharge Needle
Discharge Needle Holder
Ceramic Protection Tube
Nozzle Head
2
3
4
1
Product Maintenance
The AP-AZ9502 High-Frequency Ionizing Nozzle undergoes rigorous testing, inspection, and high-temperature
aging processes before leaving the factory, and its performance fully meets the relevant indicators stated in
the instruction manual.
Anping Company makes the following commitment to users: Within one year from the date of user purchase,
the company will repair or replace free of charge any components found to be defective upon inspection
by the company. After one year, only the cost of parts will be charged, with labor fees waived entirely. This
commitment does not apply under the following circumstances: the equipment has been modified, misused,
disassembled/reassembled by the user, or repaired by other service departments.
Except for the component repair or replacement specified herein, AP&T shall not bear any responsibility
arising from product misuse or accidents.
Before installing and using this equipment, please read the instruction manual carefully.
This equipment should not be used in environments with >70% humidity.
It is strictly prohibited to use this equipment in flammable and explosive environments.
Unauthorized disassembly of the product is strictly prohibited. Internal maintenance and repairs must be
performed by qualified personnel.
The product must not come into contact with conductive liquids, otherwise malfunctions may occur, leading
to electric shock or fire.
When inspecting or replacing the product, the power must be turned off, otherwise it may cause electric
shock or fire.
The product is specifically designed for static elimination. Using it for other purposes is strictly prohibited. Any
improper use may cause machine failure, electric shock, fire, or other hazards.
When the power is on, it is strictly forbidden to touch the electrode needle, as this can easily cause
malfunctions and electric shock accidents.
The electrode needle is a sharp metal object; please handle with care.
Before powering on the product, please check the specifications of the provided power supply. Any power
supply that does not meet the specifications may cause damage or even failure to the product.
Please regularly inspect the product's power cord. If it is damaged, replace it immediately, otherwise it may
easily cause electric leakage, operational abnormalities, and other issues.
When using the air nozzle, a compressed air purification and filtration device should be installed at the air
source connection to ensure the gas entering the nozzle body is dry and clean. This prevents moisture,
oil, etc., from the air source from entering the nozzle area and causing high-voltage short circuits, product
damage, and affecting normal use (recommended pressure dew point ≤ -20° C).
Safety Warnings
After-Sales Service
Name Picture Part No.
Specs
Quantity
Note
Mounting Bracket AP8038046
55x25 M3x2 Slot Hole Spacing 45mm x
7mm
1 Standard Accessory
Power Adapter AP4705015
Model: T6-2400500 input:100-240V 50-
60Hz,0.3A Output:24V -0.5A
1 Standard Accessory
Custom Cable:
Single RJ45 to
DC5521 Female
8WXI00022 RJ45-DC5221 Female 2.5M 1 Standard Accessory
Black Shielded
Cable, Single
8WXI00002 FUTP CAT.5E 26AWG 4 Pair PVC Sheath 1 Standard Accessory
Power Adapter AP2930003
GRT-240200 DC24V 2A P/N:1/2+ 5/6-
Port Metal PE
1
Optional for Host Monitor-
ing System (IMS)
National Standard
Power Cord
8YXG25110 Standard 1.8m, Optional 3m/5m 1
Optional for Host Monitor-
ing System (IMS)
Black Shielded
Cable, Dual RJ45
8WXI00004 Standard 2.5m, Optional 5m/10m 2
Optional for Host Monitor-
ing System (IMS)
Interface
Converter
AP2253003 USB to 485 Signal Converter 1
Optional for Host Monitor-
ing System (IMS)
Air Pipe Adapter AP8653020
G1/8 to M10x1.0 Total Height 22mm
(Compatible with ø6/ø8 Air Connectors)
1 Custom Optional Accessory
Air Shower Pipe AP8653019 M10X1.0 to M7x1.0 1 Custom Optional Accessory
Bamboo Pipe
Adapter
AP8653021 M10x1.0Z to M10x0.75 1 Custom Optional Accessory
Air Shower Pipe AP6210009 SUS316 300mm x 10mm Hole Pitch 1 Custom Optional Accessory
Product Packaging Accessories