6.6.4.1 Pick Up Component Option
NOTE 6
Before you can activate this option you must have already loaded a package form number. If this
is not the case, the button will remain inactive.
6
Fig. 6.6 - 15 Test component menu, Pick up component option
When this option is activated the following actions are started: 6
A component is picked up from a specific track.
If there already is a component beneath the component camera, it will be discarded.
The options Test and Measure can be clicked on.
SIPLACE 80S-20/F4 User Manual 6 Vision functions
Software version SR.407.xx 01/2001 US Edition 6.6 Test Component
293
6.6.4.2 Display Component Option
NOTE 6
Before you can activate this option you must have already loaded a package form number.
6
Fig. 6.6 - 16 Test component menu, Display component option
When this option is activated the following actions are started: 6
The teach command will be given.
The vision system generates the outside contours of the component from the synthetic descrip-
tion.
The video image with the real camera image and the model overlaid on it will be displayed on
the screen.
The header with commentaries is displayed.
The operator can now check the synthetic description visually against the real component. 6